5
-
A + + + , A + + , A+
S how error mode when push ‘Freezer temp’ and ‘express Freezing’ button, simultaneously for 1 sec. (All on Mode)
MIC OM E rror C ode
1
Normal
temperature.
-
Display S witch is normal
Check the connection of
each sensor
S napping of defrost heater
and Temperature fuse,
P oor of Heater relay
operation, Drain is
blocked.
B L D C M o t o r w i r e
d i s c o n n e c t i o n ,
D r i v e I C a n d T R E r r o r
2
F ailure of Freezer
S ensor
C ut or short circuit wire
3
F ailure of R efrigerator
S ensor
C ut or short circuit wire
4
F ailure of Freezer
Defrost S ensor
C ut or short circuit wire
5
F ailure of outdoor
S ensor
C ut or short circuit wire
6
7
P oor of
F reezer Defrost
120min later After starting defrost. If
sensor doesn’t be over 8°C .
9
10
Cycle Error
F ailure of B LDC FAN
Motor
Feedback signal was not
detected within 65sec
from BLDC Fan motor
temperature isn’t under
the 3.5deg within 10min,
after LQC mode started
Check the Compressor
Cooling power
Freezer
Int e rior
Exterior
NO
Item
E rror C ode
C ontents
R emarks
FS E
FS
rS E
rS
dS F
rt E
rt
dH F
FF E
FF
8
F a i lu r e o f B L D C
C - FA N M oto r
C F E
C F E
F U
C O
-
E
►
Communication Error
If there is no signal for
communication between mai
n and display PCB.
Lead wire s hort between
main and Dis play P C B ,
trans mis s ion T R and
receiving part.
Содержание GBB530***F Series
Страница 35: ... 35 CIR CUIT DIAGR AM A ...
Страница 36: ... 36 CIR CUIT DIAGR AM Linear A ...
Страница 37: ... 37 CIR CUIT DIAGR AM Linear A FLB compressor ...
Страница 39: ...CIR CUIT DIAGR AM 39 A A ...
Страница 40: ...CIR CUIT DIAGR AM 40 A HIT Model MEZ64799002 ...
Страница 41: ...CIR CUIT DIAGR AM 41 A BMG ...
Страница 42: ...CIR CUIT DIAGR AM 4 A BMG ...
Страница 43: ...CIR CUIT DIAGR AM 4 A FMA ...
Страница 50: ... Figure 24 LOKRING TOOL Figure 23 LOKRING TR OUB LE S HOOTING Mechanical Part ...
Страница 64: ... 6 2 Dis play PCB P No E B R 7 6 4 5 6 7 Picture PCB Picture ACQ838523 EBR364958 ...
Страница 92: ...P No M FEB 2015 Printed in Poland ...