Troubleshooting
P201
PV A Over Volt P
Voltage level of PV A is higher
than the limitation.
Automatically reboot within a
minute.
P202
PV B Over Volt P
Voltage level of PV B is higher
than the limitation.
Automatically reboot within a
minute.
P203
PV A Over Curr P
Current level of PV A is higher
than the limitation.
Automatically reboot within a
minute.
P204
PV B Over Curr P
Current level of PV B is higher
than the limitation.
Automatically reboot within a
minute.
P205
PV Insulation P
Insulation resistance level on PV
is lower than the limitation.
Automatically reboot within a
minute.
P206
Batt Over Volt P
Voltage level of the battery is
higher than the limitation.
Automatically reboot within a
minute.
P207
Batt Over Curr P
Current level of the battery is
higher than the limitation.
Automatically reboot within a
minute.
P208
DC Link Over Volt P
Voltage level of the DC Link is
higher than the limitation.
Automatically reboot within a
minute.
P209
Grid Under Volt P
Voltage level of the grid is lower
than the limitation.
Automatically reboot within a
minute.
P210
Grid Over Volt P
Voltage level of the grid is
higher than the limitation.
Automatically reboot within a
minute.
P211
Grid Over Curr P
Current level of the grid is
higher than the limitation.
Automatically reboot within a
minute.
P212
Grid Under Freq P
Frequency level of the grid is
lower than the limitation.
Automatically reboot within a
minute.
P213
Grid Over Freq P
Frequency level of the grid is
higher than the limitation.
Automatically reboot within a
minute.
P214
Residual Curr P
Residual current level is higher
than the limitation
Automatically reboot within a
minute.
P215
Over Temperature P
The PCS temperature is higher
than the limitation.
Automatically reboot within a
minute.
P216
Anti Islanding P
There was a power failure.
Automatically reboot within
a minute. after the power
recovery.
P217
Grid Avg Volt P
An average voltage level within
10 minutes is higher than the
limitation.
Automatically reboot within a
minute.
P218
Grid DC Curr P
DC offset current is added on
Grid
Automatically reboot within a
minute.
P219
PCS Starting Error
The Error is happened when
PCS is running in the starting
sequence.
Automatically reboot within a
minute.
P220
Batt Under Volt P
Voltage level of the battery is
lower than the limitation
Contact service center
P101
Batt Over Volt W
Voltage level of Battery is
higher than the limitation.
Warning