25
ENGLISH
Venting the Dryer (cont.)
routing and connecting ductwork
INCORRECT VENTING
CORRECT VENTING
NOTE
Deduct 6 ft. (1.8 m) for each additional elbow. It is not
recommended to use more than four 90° elbows.
NOTE
Follow the guidelines below to maximize drying
performance and reduce lint buildup and
condensation in the ductwork.
Ductwork and fittings are NOT included and must be
purchased separately.
• Use 4-inch (10.2 cm) diameter rigid or semirigid
metal ductwork.
• The exhaust duct run should be as short as possible.
• Use as few elbow joints as possible.
• The male end of each section of exhaust duct must
point away from the dryer.
• Use duct tape on all duct joints.
• Insulate ductwork that runs through unheated areas
in order to reduce condensation and lint buildup on
duct surfaces.
• Incorrect or inadequate exhaust systems are not
covered by the dryer warranty. Failures or poor
performance caused by such exhaust systems will
not be covered by the dryer warranty.
ductwork
WALL CAP TYPE
0
1
2
3
4
0
1
2
3
4
NUMBER OF
90° ELBOWS
MAXIMUM LENGTH OF
4-INCH DIAMETER
RIGID METAL DUCT
65 ft. (19.8 m)
55 ft. (16.8 m)
47 ft. (14.3 m)
36 ft. (11.0 m)
28 ft. (8.5 m)
55 ft. (16.8 m)
47 ft. (14.3 m )
41 ft. (12.5 m)
30 ft. (9.1 m)
22 ft. (6.7 m)
Recommended
Use only for
short run
installations
4”
(10.2 cm)
4”
(10.2 cm)
INSTALLATION INSTRUCTIONS
2
1/2
”
(6.35 cm)
Содержание DT22BSSG
Страница 52: ...51 ENGLISH ...
Страница 53: ...52 ...
Страница 54: ...53 ENGLISH ...
Страница 55: ...54 ...
Страница 106: ...51 ESPAÑOL ...
Страница 107: ...52 ...
Страница 108: ......
Страница 109: ......