Normal Maintenance/Long-term Storage
Normal Maintenance
Long-term Storage
18
• Wipe with soft cloth.
• Do not wipe the Main Unit
with water.
If washing the Main Unit
with water, insulation gets
contaminated.
• Never use things as below.
These cause damage to plastics.
(thinner, benzene, acid, scrubber
etc.)
• When using cloth with chemicals,
follow the guideline.
Maintenance of Drain Bucket
Main Unit
Clean the bucket with water.
In order to use safely, check the followings at
least every 6 months or a year:
Check periodically
Check if power cord
is too hot.
Check if power
cord is damaged.
Sponge, etc.
Float
If water remains in the Float, the
"AUTO SHUT-OFF" switch may not work
properly, so wipes water completely.
Soft Cloth
CAUTION
Unplug the Power
Cord from AC outlet.
Remove water in the bucket
completely.
• After removing the lid of the bucket, wipe
the water inside the bucket.
Let the filter dry for about 6 hours where
sunlight will not fall directly on the filter
and where ventilation is good. Then
cover the filter and store in upright
position.
Clean the filter.
• Never wash the Deodorizing Air Purifying
Filter with water.
• Otherwise, this filter will malfunction.
Deodorizing Air