4.14 Indicator LED Trouble
- 80 -
4. Trouble Shooting
Test Points
Circuit Diagram
Checking Flow
CN201
21 22
RLED
G
R225
10K
R223 17K
UMX1NTN
4
5
6
1
2
3
0
0
R261
GREEN LED
R263
RED LED
GLED
RED_LED
Q201
R264
NA
R262
0
R226 47K
R227
47K
VBAT of U102 is
3.6~4.2V?
Are both LEDs not
working?
BACKLIGHT WILL
WORK PROPERLY.
Replace Q201, and try again.
Check the VBAT of U102.
Check the soldering or replace LEDs not working.
No
No
Yes
Yes
START
Figure 4-26.
R226 R227 R264 R262
Q201
R225 R229