- 75 -
4. Trouble Shooting
START
Check the magnet
in the folder side.
Place the magnet properly.
Resolder U103.
Resolder R142 & U103.
Replace U103.
Replace U102.
Voltage at Pin 6
of U103 = 2.8V ?
Open Folder.
Voltage at Pin 1 of U103
= 2.8V ?
Does it work properly?
FOLDER WILL WORK
PROPERLY.
Close Folder or
get close any magnet to U103.
Voltage at Pin 1 of U103
= 0V ?
Voltage VEXT1 of U102
= 2.8V?
No
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Redownload software
or change the main board.
Checking Flow