4. Trouble Shooting
- 66 -
Checking Flow
Waveform
SETTING : After initialize Agilent 8960, Test EGSM, DCS mode
START
Check the signal level of
RCVP & RCVN at R414, R416. Are
these voltage is about 1.2V?
Check the signal level at R415.
Is it almost 0?
Check the soldering
R414 & R416
Re-soldering
R414, R416
Check the soldering
of U402
Replace the Main board.
ABB is out of order.
Re-soldering U402
Replace the dual mode speaker
Check the contact state of dual
mode speaker.
The dual mode speaker will work
properly.
Replace U402
No
No
No
No
No
Yes
Yes
Yes
Yes
Graph 4-10.