Room Air Conditioner
Installation
2) Connection of piping-Indoor
1. Remove the 2 screws of right side panel.
2. Remove the front right side panel by the arrow.
■
The connector can be disconnected by pulling it
while pressing the connector's hook.
■
Remove the 1 screw for fixing lower panel.
3. Remove the lower panel by the arrow.
■
Take care not to scratch the wall and mat to
drop.
1. Route the indoor tubing and the drain hose in the
direction of rear left.
2. Insert the connecting cable into the indoor unit
from the outdoor unit through the piping hole.
■
Do not connect the cable to the indoor unit.
■
Make a small loop with the cable for easy
connection later.
Right side panel
Drain hose
Main PCB
Lower panel
Lower panel
For left rear piping
CAUTION
When install, make sure that the
remaining parts must be
removed clearly so as not to
damage the piping and drain
hose, especially power cord and
connecting cable.
Содержание AS-C306MSeries
Страница 43: ...Service Manual 43 Schematic Diagram Heat Pump Series Outdoor Unit Model AS H306 Series 5 5 4 4 3 3 2 2 1 1 ...
Страница 44: ...44 Room Air Conditioner Schematic Diagram Model AS H366 Series ...
Страница 45: ...Service Manual 45 Schematic Diagram 5 5 4 4 3 3 2 2 1 1 Model AS C306 Series ...
Страница 46: ...46 Room Air Conditioner Schematic Diagram Model AS C366 Series ...
Страница 49: ...Service Manual 49 Schematic Diagram Electronic Control Device INDOOR UNIT P W B ASSEMBLY ...
Страница 51: ...Service Manual 51 Schematic Diagram DISPLAY P W B ASM ...
Страница 73: ...Service Manual 73 Memo ...
Страница 74: ...74 Room Air Conditioner Memo ...
Страница 75: ...P No 3828A20347D Printed in Korea ...