Service Manual 29
Installation
1. Open panel front
■
First,Pull the grille bottom, then remove screws(2
pieces), and close grille bottom again.
■
The moment of lifting the both lower parts of panel
front, you can hear sound this panel came out, In
this time panel front is separated
■
After pull down this panel a bit, and separate con-
necting wire with product.
Pipe hole
Side cover
Panel Front
Connector
2. Cover pipe and cover side remove
■
Remove two screws(for fixing cover pipe)
■
Pull up the cover side of desired connecting direc-
tion, then cover side is separated.
■
In case connecting direction is left or right, path
through the hole of cover side.
When connecting pipe path through rear wall, don’t
remove the hole.
3. Drain hose junction
■
Remove the rubber stopple of desired drain direc-
tion.
■
As the following picture, Insert drain hose in the
handle of drain pan, and join drain hose and con-
necting hose.
rubber cap
Only one
desiring direction
Connecting
part
Adhesive
Drain
hose
3) Preparing work for Installation
After removing the pipe hole, cut the burr for safety.