Service Manual 63
Cycle Troubleshooting Guide
9. Voltage of Connectors according to Indoor Fan Speed
4
3
2
1
1
1
2
3
4
INDOOR
FAN
MOTOR
INDOOR PWB ASSY
Connecting wires
between Indoor
and Outdoor
Indoor
Connecting Terminal
Outdoor
Connecting Terminal
Input Power
TAB-N
RY-COMP-A
RY-COMP-B
CN-DC/DC
BL
BK
BR
RD
BL
BK
BR
RD
+-
12
32
42
12
32
42
12
32
42
OUTDOO
R CN-DC/DC
INDOOR
CN-DC/DC
INDOOR
CN-MOTOR
No. of pins
MODELS
CONNELTORS
S-Hi
Hi
Med
Low
Off
34.0
32.0
27.8
24.1
34.0
32.0
27.8
24.1
34.0
32.0
27.8
24.1
0.0
5.0
5.0
5.0
5.0
5.0
0~5
0~5
0~5
0~5
5.0
0~12
0~12
0~12
0~12
0~12
17.0
17.0
17.0
17.0
17.0
0.0
0~12
0~12
0~12
0~12
0~12
17.0
17.0
17.0
17.0
17.0
0.0
18K
DC Voltage(
±
10%)
34
34
Содержание ARTCOOL LA180CP
Страница 16: ...16 Room Air Conditioner Wiring Diagram 18K Cooling Only Models Wiring Diagram Indoor Unit Outdoor Unit ...
Страница 65: ...Electronic Control Device TOP VIEW BOTTOM VIEW MAIN PWB ASSY Outdoor Unit ...
Страница 66: ...66 Room Air Conditioner Electronic Control Device TOP VIEW BOTTOM VIEW DISPLAY PWB ASSEMBLY ...
Страница 68: ...68 Room Air Conditioner Schematic Diagram Outdoor Unit ...
Страница 73: ...P No 3828A20065Y Printed in Korea ...