Single Zone art Cool Premier Wall Mount outdoor unit Clearance
PlaCEMEnt ConSidErationS
Outdoor Installation
Minimum
27-19/32
Minimum
11-13/16
ODU Service Access & Clearances
Unit: Inch
In order to have successful service access to the out door unit,
see Figure 14 for minimum spacing.
When installing multiple outdoor units, see Figure 15 for correct
spacing requirements.
Minimum
Minimum
11-13/16
78-3/4
23-19/32
27-19/32
Unit: Inch
Multiple ODUs
Service Access & Clearances
Figure 14: oDU Service Access Clearance - Single Unit
Figure 15: oDU Service Access Clearance - Multiple Units
More than 8 inches
More than 4 inches
More than
4 inches
At least 6.5 feet from the floor
indoor unit Clearance
Follow recommended best practices when choosing an indoor loca-
tion for the Single Zone indoor unit.
Do not install near doorway.
• Keep unit away from any indoor steam or excessive
heat to avoid equipment malfunction.
• No obstacles should be placed around unit to obstruct air flow.
• Condensation drain (leakage piping) should be routed away
from the unit to avoid equipment damage due to moisture.
• Clearance gap between any wall or enclosure and
the left or right side of the unit must be greater
than 4 inches to allow for adequate air flow.
• From the top of the unit to the ceiling there must
greater than 8 inches of clearance to allow for
adequate air flow and service access.
• Unit should be at least 6.5 feet from the floor for adequate clearance.