18 | ProduCT dATA
Art Cool Premier W
all Mounted Engineering Manual
Due to our policy of continuous product innovation, some specifications may change without notification.
rEFrigErant FloW diagraM
LAn090HYV, LAn120HYV
LAu090HYV, LAu120HYV
LOC. Description PCB Connector
Th1 Indoor air temperature thermistor CN-TH1(Indoor)
Th3 Water level sensor (Option) CN-TH2 (Indoor)
Th4 Evaporating middle temperature thermistor CN-TH3 (Indoor)
Th5 Discharge pipe temperature thermistor CN-TH2 (OUTDOOR)
Th6 Heat exchanger temperature thermistor CN-TH1(OUTDOOR)
Th7 Outdoor air temperature thermistor CN-TH1(OUTDOOR)
EEV : Electronic Expansion Valve
Indoor Unit
Outdoor Unit
Heat
Exchanger
(Evaporator )
Heat
Exchanger
(Condenser )
Compressor
Accumulator
Gas Side
3-Way Valve
2-Way Valve
Liquid Side
Coolin g
Heatin g
Reversing Valve
Th1
Th6
Th3
Th7
Th4
Th5
FIELD PIPING
(Ø 1/4” Copper
Tubing)
FIELD PIPING
(Ø 3/8” Copper
Tubing )
EEV