Service Manual 17
Ceiling Cassette 4-way
Conversion Formula
kW
= Btu/h
×
0.0002931
kcal/h = Btu/h
×
0.252
CFM = CMM
×
35.3
Power Supply
Ø/V/Hz
Cooling Capacity
kW
Btu/h
Heating Capacity
kW
Btu/h
Current
Nominal running current
A
Fan
Motor Type
Fan Type
Motor Output x Number of Unit
Air Flow Rate
cmm
(H/M/L)
cfm
Capacitor
µF/Vac
Drive
Coil
Row x Column x FPI
mm
Dimensions Body
mm(inch)
(WxHxD)
Decorative Panel
mm
Weight
Body
kg(lbs)
Decorative Panel
kg(lbs)
Air Filter
Sound Level (H/M/L)
dB(A)+3
Piping
Liquid
mm(inch)
Connections
Gas
mm(inch)
Drain(OD/ID)
mm
Dehumidification Rate
l/h
Safety devices
Temperature Sensor
Referigerant
Referigerant Control
Connectable outdoor unit
Power and transmission interunit cable
No.x mm
2
Model
ATNH366DLFC
[UT36 NDC]
ATNH486DLFB
[UT48 NDB]
ATNH606DLFB
[UT60 NDB]
Indoor unit type
Ceilling Cassette - 4way
1 / 220 ~240 / 50
1 / 220 ~240 / 50
1 / 220 ~240 / 50
10.6 14.1 16.4
36,000 48,000 56,000
12.1
15.5 18.1
41,400
52,800 61,600
0.76
1.5
1.8
Induction
Induction
Induction
Turbo Fan
Turbo Fan
Turbo Fan
52.5*1
58.5*1
107*1
25 / 23 / 21
32 / 30 / 28
34 / 32 / 30
883 / 812 / 742
1059 /988 / 918
1200 / 1130 / 1059
2.5/440
6/400
6/400
Direct Drive
Direct Drive
Direct Drive
2R x 12C x 21
2R x 12C x 21
2R x 12C x 21
840*288*840(33.1*11.3*33.1)
840*288*840(33.1*11.3*33.1)
840*288*840(33.1*11.3*33.1)
950*30*950(37.4*1.2 *37.4)
950*30*950(37.4*1.2 *37.4)
950*30*950(37.4*1.2 *37.4)
32(70.4)
32(70.4)
32(70.4)
5(11)
5(11)
5(11)
Long life filter
Long life filter
Long life filter
40 / 38 / 36
43 / 41 / 39
50 / 47 / 43
6.35 (1/4)
9.52 (3/8)
9.52 (3/8)
15.88(5/8)
19.05(3/4)
19.05(3/4)
32 / 25
32 / 25
32 / 25
4.0
5.5
6.5
Fuse, Thermal protector for fan motor Fuse, Thermal protector for fan motor Fuse, Thermal protector for fan motor
Thermistor
Thermistor
Thermistor
R-410A
R-410A
R-410A
LEV
LEV
LEV
Single A
Single A
Single A
4*0.75
4*0.75
4*0.75
Note :
1. Capacities are based on the following conditions:
Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB
- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB
Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB
- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB
Piping Length - Interconnecting Piping Length 7.5m
- Level Difference of Zero.
2. Cooling/heating capacity of indoor unit can be lower when it is connected to MPS variable outdoor.
3. Wiring cable size must comply with the applicable local and national code.
Содержание ABNH186HLAB
Страница 66: ...66 Universal System Air Conditioner II Outdoor Units Introduction 67 AUUW B AUUW 0 R410A 69 ...
Страница 80: ...80 Universal System Air Conditioner MPS Inverter SINGLE A 4 Wiring Diagrams AUUW126B UU12 WUEB ...
Страница 120: ...Electronic Control Device 120 Universal System Air Conditioner Main P C B ASM A 6871A10209 B 58 Ceiling Cacsette Type ...
Страница 121: ...Electronic Control Device Service Manual 121 Ceiling Duct Type BH Series ...
Страница 122: ...Electronic Control Device 122 Universal System Air Conditioner BG BR Series ...
Страница 123: ...Electronic Control Device Service Manual 123 VE Series Ceiling Floor ...
Страница 124: ...Electronic Control Device 124 Universal System Air Conditioner VB Series ...
Страница 125: ...Service Manual 125 V Schematic Diagram Ceiling Cacsette Type 126 Ceiling Duct Type 127 Celing Floor 128 ...
Страница 126: ...Schematic Diagram 126 Universal System Air Conditioner Ceiling Cassette Type ...
Страница 127: ...Schematic Diagram Service Manual 127 Ceiling Duct Type ...
Страница 128: ...Schematic Diagram 128 Universal System Air Conditioner Ceiling Floor ...
Страница 180: ...Exploded View Replacement Parts List 180 Universal System Air Conditioner 152312 135314 137211 268712 146811 PT HFA C ...
Страница 181: ...Exploded View Replacement Parts List Service Manual 181 152312 135314 146811 137211 268712 135802 PT HDA C ...
Страница 183: ...P No 3828A22009B Printed in Korea ...