- 22 -
Electronic parts Troubleshooting Guide
Is the indoor fan operation?
1. Press cooling or fan operation
or heater operation key.
Is the output
voltage of Micom's 3PIN on
the MAIN PCB 5V?
Is the magnetic
contactor for humidifier OK?
Check the humidifier.
1. Press humidifier Key.
1. Check or exchange IC02D
on the MAIN PCB.
Is the voltage
between 1PIN of CN5 and
NEUTRAL 220V?
1. Check or exchange RY3.
Is the HUMID LCD "ON"?
1. Check the wiring or Magnetic
contactor.
2. Exchange Magnetic contactor.
YES
YES
NO
YES
YES
NO
NO
NO
YES
NO
Possible trouble 7
: No humidifier operation performed.
Содержание AB-H1208VA0
Страница 1: ...LG Large Duct Type Air Conditioner SERVICE MANUAL MODELS AB H1208VA0 ...
Страница 24: ... 24 Features of Controller 1 Circuit Diagram of Indoor PCB ...
Страница 25: ... 25 2 Circuit Diagram of BLDC Driver ...
Страница 26: ... 26 3 Circuit Diagram of Outdoor PCB ...
Страница 32: ...P No 3828A20845A June 2006 Printed in Korea ...