2
MULTI
Outdoor Unit
Multiple piping type
1. List of functions
Basic functions of Outdoor Unit
Accessory Compatibility List
Category
Functions
A2UW18GFAC
A
3
UW21GFAC
Reliability
Defrost / Deicing
O
High pressure switch
X
Phase protection
X
Restart delay (3-minutes)
O
Self diagnosis
O
Soft start
O
Convenience
Night Low Noise Operation
O
Wiring Error Check
O
Peak Control
O
Mode Lock
O
Forced Cooling Operation (Outdoor Unit)
O
SLC (Smart Load Control)
X
Note
1. O : Applied, X : Not applied
Accessory : Ordered and purchased separately the accessory package referring to the model name provided and install at field.
Accessory line-ups varies by region, so check your local catalogue or local sales material.
Category
Product
Etc
A2UW18GFAC
A
3
UW21GFAC
Central Controller
Simple
PQCSZ250S0
AC EZ
X
AC Ez Touch
PACEZA000
AC Ez Touch
X
AC Smart
PACS5A000
AC Smart 5
X
ACP
PACP5A000
ACP 5
X
AC Manager
2)
PACM5A000
AC Manager 5
X
Gateway
ODU PI485
PMNFP14A1
PI 485 Gateway
X
BACnet
PQNFB17C0
ACP BACnet
X
Lonworks
PLNWKB000
ACP Lonworks
X
ETC
PDI
PPWRDB000
PDI Standard
X
PQNUD1S40
PDI Premium
X
Note
1. O: Possible, X: Impossible, - : Not applicable
2. * : Some advanced functions controlled by individual controller cannot be operated.
3.
2)
: ACP or AC Smart is needed.
4. Compatibility of individual controller(wireless/wired remote controller) could be found with function list on Indoor Unit’s PDB.
5. If you need more detail, please refer to the
BECON
PDB or the manual of product.
(http://partner.lge.com/global : Home> Doc.Library> Product > Control(BECON))