8. Electric characteristics
39
THERMA V
Split Type
Outdoor unit
̰
Outdoor Unit and Hydro Box Unit
Model
Power Supply
for Heat Pump
Power Supply for Heater
Indoor Unit
Outdoor Unit
Phase
Volts
Hz
Circuit Breaker
(A)
Back-up Heater
DHW Tank Heater
Circuit Breaker (A)
Capacity
(kW)
Power
Supply
Capacity
(kW)
Power
Supply
Back-up
Heater
Back-up
DHW
Tank Heater
AHNW16606A3
AHUW056A3
1~
220-240V
50Hz
30
3+3
1Ø 230V
3
1Ø 230V
35
50
AHUW076A3
AHUW096A3
AHUW126A3
40
35
50
AHUW146A3
AHUW166A3
AHNW16809A3
AHUW128A3
3N~
380-415V
50Hz
20
3+3+3
3Ø 400V
20
35
AHUW148A3
AHUW168A3
[Power Supply for Heat Pump]
[Power Supply for Electric Heater]
Note
1.Voltage supplied to the unit terminals should be within the minimum and maximum range.
2.Maximum allowable voltage unbalance between phase is 2%.
3.Recommended circuit breaker type is ELCB (Earth Leakage Circuit Breaker).
ELCB
CB
Outdoor Unit
Indoor
Unit
Power Source
Communication
Switch Box
Power Source
Communication
Switch Box
ELCB
CB
Outdoor Unit
Indoor
Unit
CB
Содержание 5BPU0-02C
Страница 1: ...Air to Water Heat Pump Split Type R410A 50Hz 5BPU0 02D Replaces 5BPU0 02C P No MFL66101112 ...
Страница 3: ...General Information THERMA V Split Type 1 Model Line Up 2 Nomenclature ...
Страница 9: ...Indoor Unit THERMA V Split Type Hydro Box Unit DHW Tank Integrated Unit ...
Страница 17: ...8 THERMA V Split Type Hydro Box Unit 4 Wiring Diagrams AHNW16606A3 HN1616 NK3 ...
Страница 18: ...4 Wiring Diagrams 9 THERMA V Split Type Hydro Box Unit AHNW16809A3 HN1639 NK3 ...
Страница 31: ...THERMA V Split Type 4 Wiring diagrams 8 DHW Tank Integrated Unit Indoor unit Controller ...