5. Piping Diagram
11
THERMA V
Split Type
Hydro Box Unit
Category
Symbol
Meaning
PCB Connector
Remarks
Indoor Unit
S7
Refrigerant temperature sensor (Gas
side)
CN_PIPE_OUT
- Meaning is expressed based on Cooling
mode.
S8
Refrigerant temperature sensor
(Liquid side)
CN_PIPE_IN
S9
Entering Water temperature sensor
CN_TH3
- S9, S10 and S11 are connected at 6 pin
type connector CN_TH3.
S10
Leaving Water temperature sensor
S11
Electric heater outlet temperature
sensor
F/S
Flow Switch
CN_FLOW1
ଝ
E/HT
Electric Heater
CN_E/HEAT(A)
CN_E/HEAT(B)
- Heating capacity is divided into two level :
partial capacity by E/HEAT(A) and full
capacity by E/HEAT(A) + E/HEAT(B).-
Operating power(230 V AC 50 Hz) of
E/HEAT(A) and E/HEAT(B) are supplied by
external power source via relay connector
and ELB.
W_PUMP1
Internal Water Pump
CN_MOTOR1
- Water Pump is connected at
CN_MOTOR1
EXP/TANK
Expansion Tank
(no connector)
- Absorb volume change of heated water,
S12
Remote Air temperature sensor
CN_ROOM
- Optional accessory (sold separately)-
Model : PQRSTA0
CTR/PNL
Control Panel (or 'Remote Controller')
CN_REMO
- Pre built-in at indoor unit
2WAY V/V_1
To control water flow for Fan Coil Unit
CN_2WAY(A)
- 3rd party accessory and Field installation
(sold separately)- 2 wire NO or NC type
2way valve is supported.
M / F
Magnetic Filter
(No connector)
- 3rd party accessory and Field installation
(sold separately)- It is strongly
recommended to install an additional filter
on the heating water circuit.
Water
Heating
W/TANK
DHW Tank
(No connector)
- 3rd party accessory and Field installation
(sold separately)- Generating and storing
DHW by AWHP or built-in electric heater
B/HT
Electric Heater
CN_B/HEAT(A)
- 3rd party accessory and Field installation
(usually built-in at W/TANK)- Supplying
additional water heating capacity.
3WAY V/V_1
- Flow control for water which is
leaving from indoor unit.- Flow
direction switching between
underfloor and water tank
CN_3WAY(A)
- 3rd party accessory and Field installation
(sold separately)- SPDT type 3way valve is
supported.
CITY WATER
Water to be heated by Indoor unit and
B/HT of W/TANK
(no connector)
- Field installation
SHOWER
Water supplied to end-user
(no connector)
- Field installation
S13
W/TANK water temperature sensor
CN_TH4
- S13 and S14 are connected at 4 pin type
connector CN_TH4.- S13 is a part of DHW
tank kit.(Model:PHLTA)- S14 is a part of
solar thermal kit (Model:PHLLA)
Solar Heating
S14
Solar-heated water temperature
sensor
3WAY V/V_2
- Flow control for water which is
heated and circulated by SOLAR
THERMAL SYSTEM.- Flow direction
switching between SOLAR THERMAL
SYSTEM and W/TANK
CN_3WAY(B)
- 3rd party accessory and Field installation
(sold separately)- SPDT type 3way valve is
supported.
W_PUMP/2
External Water Pump
CN_W/PUMP(B)
- 3rd party accessory and Field installation
(sold separately)- If water pump of SOLAR
THERMAL SYSTEM is incapable of
circulation,external water pump can be
used.
SOLAR
THERMAL
SYSTEM
- This system can include following
components: Solar panel, Sensors,
Thermostats, Interim heat exchanger,
Water pump, etc.- To utilized hot
water heated by SOLAR THERMAL
SYSTEM, end-user must by LG
AWHP Solar-Kit.
(no connector)
- 3rd party accessory and Field installation
(sold separately)
Содержание 5BPU0-02C
Страница 1: ...Air to Water Heat Pump Split Type R410A 50Hz 5BPU0 02D Replaces 5BPU0 02C P No MFL66101112 ...
Страница 3: ...General Information THERMA V Split Type 1 Model Line Up 2 Nomenclature ...
Страница 9: ...Indoor Unit THERMA V Split Type Hydro Box Unit DHW Tank Integrated Unit ...
Страница 17: ...8 THERMA V Split Type Hydro Box Unit 4 Wiring Diagrams AHNW16606A3 HN1616 NK3 ...
Страница 18: ...4 Wiring Diagrams 9 THERMA V Split Type Hydro Box Unit AHNW16809A3 HN1639 NK3 ...
Страница 31: ...THERMA V Split Type 4 Wiring diagrams 8 DHW Tank Integrated Unit Indoor unit Controller ...