2. Specifications
5
THERMA V
Split Type
Hydro Box Unit
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Sound Level Values are measured at Noise Measuring chamber accordance with standard. Therefore, these values depend on the ambient conditions
and values are normally higher in actual operation.
4. Performances are based on the following conditions :
• Cooling : Inlet/Outlet Water Temp. 23°C/18°C, Outdoor Air Temp. 35°CDB / 24°CWB
• Heating : Inlet/Outlet Water Temp. 30°C/35°C, Outdoor Air Temp. 7°CDB / 6°CWB
• Interconnected Pipe Length is standard length and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
5. This product contains Fluorinated greenhouse gases.
6. Sound Performances are based on the following conditions.
• Sound Power Level : Measured according to EN14825.
• Sound Pressure Level : Calculated value according to distance of sound power.
* : This specification is data when electric heater is not used.
** : This information is given as a guideline about the connection of DHW tank.
*** : This Accessory Kit is required only when you want to user the electric heater function at DHW tank. If not, it’s not necessary.
Therma V indoor unit it self already has electric heater (back up heating) function.
Electrical Specification
AHNW16606A3
[HN1616 NK3]
AHNW16809A3
[HN1639 NK3]
Electric Heater
Type
-
Sheath
Sheath
Number of Heating Coil
EA
2
3
Capacity Combination
kW
3.0 + 3.0
3.0 + 3.0 + 3.0
Operation
-
Automatic
Automatic
Heating Steps
Step
2
2
Power Supply
V, Ø, Hz
1, 220-240, 50
3, 380-415, 50
Rated Current
A
25.0
25.0
Maximum Current
A
32.0
32.0
Wiring
Connections
Power and Communication Cable
(Included Earth)
No. x
mm²
3 x 1.5 (H07RN-F)
3 x 1.5 (H07RN-F)
Содержание 5BPU0-02C
Страница 1: ...Air to Water Heat Pump Split Type R410A 50Hz 5BPU0 02D Replaces 5BPU0 02C P No MFL66101112 ...
Страница 3: ...General Information THERMA V Split Type 1 Model Line Up 2 Nomenclature ...
Страница 9: ...Indoor Unit THERMA V Split Type Hydro Box Unit DHW Tank Integrated Unit ...
Страница 17: ...8 THERMA V Split Type Hydro Box Unit 4 Wiring Diagrams AHNW16606A3 HN1616 NK3 ...
Страница 18: ...4 Wiring Diagrams 9 THERMA V Split Type Hydro Box Unit AHNW16809A3 HN1639 NK3 ...
Страница 31: ...THERMA V Split Type 4 Wiring diagrams 8 DHW Tank Integrated Unit Indoor unit Controller ...