90
August 2009 Plasma 50PS80
Control Board LVDS P5 Connector
Control Board LVDS P5 Connector
LVDS Cable Connector Removal
Press Inward
Press Inward
P6 Auto Gen:
Jump pin 1 to 2, a series of patterns will be produced on screen.
1
The pin connections on the LVDS plug are too close
together for safe readings, use Test Points. To remove the
LVDS cable, press the two locking tabs inward, then rock
the connector side to side while pulling out on the
connector.
If a video problem is encountered, to eliminate all Panel
boards, remove the LVDS cable and then jump the Auto Gen
connector pin 1 and 2. If the picture is OK, the Power Supply,
Y-SUS, Z-SUS, Y-Drives, X-Boards, TCPs and the Panel are
OK. And most likely the Control board is OK too.