64
July 2010 50PJ350 Plasma
Diode Mode Readings
taken with all connectors
Disconnected.
DVM in Diode Mode.
Y
Y
-
-
SUS P101 to Control P111 Plug Voltage Checks
SUS P101 to Control P111 Plug Voltage Checks
There are No Stand By
Voltages on this Connector
Gnd
Gnd
Gnd
30
1.18V
2.08V
Delta_VY_Det
15
1.14V
0.06V
YSUS_UP_IN
29
1.19V
1.78V
OC2
14
1.14V
1.08V
Pass_Top
28
Gnd
Gnd
Gnd
13
1.14V
0.62V
YER_UP
27
Gnd
Gnd
Gnd
12
1.14V
1.01V
Ramp_Slope
26
1.75V
0V
OE
11
1.14V
0.95V
YSUS_DN_IN
25
Gnd
Gnd
Gnd
10
1.14V
0.24V
SET_UP
24
1.54V
0V
CTRL_OE
9
1.14V
0V
YER_DN
23
Gnd
Gnd
Gnd
8
1.14V
0.59V
CLK
22
1.19V
4.9V
+5V
7
1.14V
1.34V
Slope_Rate_Sel
21
1.19V
4.9V
+5V
6
1.14V
1.97V
STB
20
1.19V
4.9V
+5V
5
1.14V
0.03V
Det_Level_Sel
19
1.19V
4.9V
+5V
4
1.14V
1.43V
OC1
18
1.61V
16V
+15V
3
1.14V
2.09V
SET_ON
17
1.61V
16V
+15V
2
1.02V
0V
DATA
16
1.61V
16V
+15V
1
Diode
Run
Label
Pin
Diode
Run
Label
Pin
P101 Connector "Y-SUS" to P111 "Control"
c