56
July 2010 50PJ350 Plasma
Y
Y
-
-
SUS Board P212 Connector to P205 Lower Y
SUS Board P212 Connector to P205 Lower Y
-
-
Drive (Logic and FG5V)
Drive (Logic and FG5V)
Y-Drive Lower
Y-SUS Board
TIP: Use Scan Screw Lugs to test for Y-Scan signal if the Y-Drive boards are removed.
FG5V (4.9V) measured from Pins 15 or 16
To Floating Gnd
Use screw just above P212 on the Y-SUS
P205
P212
TIP: Connectors do not come with a new Y-SUS or Y-Drives.
FGnd
c