54
206-4340
*
PCS150R and later Pro:Centric servers do not support HRC or IRC cable channel frequencies.
(Continued from previous page)
3.
Refer to the appropriate subsection below to configure the TV’s Pro:Centric settings to match
those of the Pro:Centric server.
While the Pro:Centric application itself is an additional feature (see step 4), the appropriate
Pro:Centric server configuration must be completed to enable TV E-Z Installation (boot logo,
configuration, and software) data downloads and, if configured, the Pro:Centric application
download.
RF Configuration
For TVs in Pass-through Mode or FTG Mode via CPU, if the Data Channel is left at its default
value (255), the TV’s Data Channel Auto Search feature will be enabled. See Installer Menu item
119 DATA CHANNEL description on page 34 for further information.
To change Data Channel setting:
• Select/highlight the
Data Channel
field, and then in the subsequent pop-up window, either key
in or use the Left/Right arrow keys to select the RF channel number that will be used by the
Pro:Centric server as its data channel. The Data Channel value can be set from 0 (disabled) to
135.
*
• Select
Close
and press
OK
to save your setting and return to the Pro:Centric Menu.
Note:
If the Data Channel has already been set in the Installer Menu (Installer Menu item 119)
or in the EZ-Manager Wizard, the specified channel will appear in this field. If you change the
Data Channel in this menu, Installer Menu item 119 will now show the value you entered here.
IP Configuration
Note:
If the server IP address and port number have already been set in the EZ-Manager
Wizard, the specified data will be reflected in the fields displayed.
Note:
Setting the Media Type to “IP” automatically sets the Data Channel field in the
Pro:Centric Menu and item 119 DATA CHANNEL in the Installer Menu to 253. You cannot alter
this setting unless you revert Media Type to “RF.” Also, it is not possible to direct enter “253” in
the Data Channel field or in the Installer Menu.
• Select/highlight the
P:C IP Setting
field, and then in the subsequent pop-up window, either key
in or use the Left/Right arrow keys to select the appropriate values for the Pro:Centric server
IP address and port number. The IP address must match the IPv4 multicast address and the
port number must match the port number that is set in the Pro:Centric server.
• Select
Close
and press
OK
to save your settings and return to the Pro:Centric Menu.
4. Select/highlight the
Mode
field, and
press
OK
. Then, use the Up/Down arrow keys to select
the appropriate Pro:Centric Application Mode setting—
Configuration Only
or
GEM
(Java). If
the Pro:Centric Mode is set to “Configuration Only,” Pro:Centric application data will not be
downloaded.
IP Environment Setup (Cont.)
(Continued on next page)