32
Installation Test (Duct Check) (cont.)
• Check the Error Code before you call for service
• Check the duct condition
If the FLOW SENSE
TM
LED is turned on, check the
exhaust system for restrictions and damage. Repair or
replace the exhaust system as needed.
Error Code
Possible Causes
Solutions
tE1
or
tE2
• Temperature sensor failure
• Turn off the dryer and call for service.
HS
• Humidity Sensor failure.
• Turn off the dryer and call for service.
PS
or
PF
or
nP
• Electric dryer power cord is not
connected correctly, or house power
supply is incorrect.
• House fuse is blown, circuit breaker has
tripped, or power outage has occurred.
• Check the power supply or the connection of
power cord to the terminal block. Refer to the
Connecting electric dryers
section of this
manual for complete instructions.
• Reset circuit breaker or replace fuse. Do not
increase the fuse capacity. If the problem is a
circuit overload, have it corrected by a quali-
fied electrician.
Restricted or Blocked Airflow
Avoid long runs or runs with multiple elbows or
bends.
Excess or crushed
transition duct
Too many elbows or
exhaust too long
Check for blockages and lint buildup.
Make sure the ductwork is not crushed or restricted.
Crushed or
damaged
exhaust
Lint buildup
or blockage
NOTE
When the dryer is first installed, this test should be
performed to alert you to any existing problems with
the exhaust duct in your home. However, since the
test performed during normal operation provides
more accurate information on the condition of the
exhaust duct than does the installation test, the num-
ber of bars displayed during the two tests may not be
the same.
Do not interrupt the test cycle, as this could result in
inaccurate results.
Even if no bars are displayed during the test cycle,
some restrictions may still be present in the exhaust
system. Refer to the Venting the Dryer section of this
manual for complete exhaust system and venting
requirements.
Your dryer features Flow Sense™, an innovative sens-
ing system that automatically detects blockages and
restrictions in dryer ductwork. Keeping ductwork
clean of lint buildup and free of restrictions allows
clothes to dry faster and reduces energy use.
iNSTALLATiON
MFL67731093_en_170718.indd 32
2017.7.18 1:52:26 PM
Содержание DleX9500 Series
Страница 52: ...MFL67731093_en_170718 indd 52 2017 7 18 1 52 53 PM ...
Страница 104: ...52 MFL67731093_sp_170718 indd 52 2017 7 18 2 12 42 PM ...
Страница 105: ...53 ESPAÑOL MFL67731093_sp_170718 indd 53 2017 7 18 2 12 42 PM ...
Страница 106: ...54 MFL67731093_sp_170718 indd 54 2017 7 18 2 12 42 PM ...
Страница 107: ...MFL67731093_sp_170718 indd 55 2017 7 18 2 12 42 PM ...