21
ENGLISH
Venting the Dryer (cont.)
routIng and connectIng ductWork
INCORRECT VENTINg
CORRECT VENTINg
NOTE
Deduct 6 ft. (1.8 m) for each additional elbow. Use of
more than four 90* elbows is not recommended.
NOTE
Follow the guidelines below to maximize drying
performance and reduce lint buildup and
condensation in the ductwork.
Ductwork and fittings are NOT included and must be
purchased separately.
• Use 4-inch (10.2 cm) diameter rigid or semirigid
metal ductwork.
• The exhaust duct run should be as short as possible.
• Use as few elbow joints as possible.
• The male end of each section of exhaust duct must
point away from the dryer.
• Use duct tape on all duct joints.
• Insulate ductwork that runs through unheated areas
in order to reduce condensation and lint buildup on
duct surfaces.
• Failure to exhaust the dryer correctly will void the
dryer’s warranty.
ductwork
WALL CAP TYPE
0
1
2
3
4
0
1
2
3
4
NUmBER OF
90° ELBOWS
mAXImUm LENgTH OF
4-INCH DIAmETER
RIgID mETAL DUCT
65 ft. (19.8 m)
55 ft. (16.8 m)
47 ft. (14.3 m)
36 ft. (11.0 m)
28 ft. (8.5 m)
55 ft. (16.8 m)
47 ft. (14.3 m )
41 ft. (12.5 m)
30 ft. (9.1 m)
22 ft. (6.7 m)
Recommended
Use only for
short run
installations
4”
(10.2 cm)
4”
(10.2 cm)
2
2
/
4
”
(6.35 cm)
iNSTALLATiON
MFL67731093_en_170718.indd 21
2017.7.18 1:52:1 PM
Содержание DleX9500 Series
Страница 52: ...MFL67731093_en_170718 indd 52 2017 7 18 1 52 53 PM ...
Страница 104: ...52 MFL67731093_sp_170718 indd 52 2017 7 18 2 12 42 PM ...
Страница 105: ...53 ESPAÑOL MFL67731093_sp_170718 indd 53 2017 7 18 2 12 42 PM ...
Страница 106: ...54 MFL67731093_sp_170718 indd 54 2017 7 18 2 12 42 PM ...
Страница 107: ...MFL67731093_sp_170718 indd 55 2017 7 18 2 12 42 PM ...