PRE-INSTALLATION OF THE LIFT GATE
1. Measure from the bottom of the cross members to the ground. If this measurement is less than
47 inches, spacers will not be required. This measurement must be 41.5 inches minimum in
order to yield 14 inches ground clearance for the gate. If the measurement is more than 47
inches, the amount in excess of 47 inches is the height of the spacer that must be added to the
four channels at the top of the Outer Slide. See Sketches 1 and 2.
2. Check the side door threshold. See Sketch 3. For the platform to properly enter the opening,
dimension “B” must be at least 1.5 times dimension “A”.