![LEYBOLD TURBOTRONIK NT 20 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/leybold/turbotronik-nt-20/turbotronik-nt-20_operating-instructions-manual_1890872022.webp)
Connection
22
GA 05.208/12 - 05/2003
Key to Fig. 5
Inputs
1 REMOTE
“-”
2 REMOTE
“+”
3 “STOP”
“-”
4 “STOP”
“+”
5 “START”
“-”
6 “START”
“+”
7 HEATING
”-”
8 HEATING
“+”
Outputs (Relais)
9 GND
10 + 15 V
11 NORMAL
12 NORMAL
13 FAILURE NO (normally open)
14 FAILURE C (Common)
15 FAILURE NC (normally closed)
16 ACCEL
17 ACCEL
18 Optional
Trigger for
19 Optional
link circuit
20 Optional
current
Fig. 5 TURBOTRONIK NT 20, rear panel;
assigment of the terminal strip (3/5)
Fig. 4 Switching examples for the motor connection of the forevacuum pump
Power <750 VA /single-phase
Power >750 VA /single-phase
three-phase
FAILURE
FAILURE
Relay status
VALVE
HEATER
FAN
FOREPUMP
ACCEL
13/14
14/15
NORMAL
(3/11)
(3/9)
(3/8)
(3/2)
Fig. 5
Fig. 5
Fig. 5
Power off
open
open
open
open
open
open
closed
open
STOP
open
open
open
open
open
open
closed
open
Delayed start-up device
Mains power
open
open
closed
closed
open
closed
open
applied
Acceleration
Mains power
open
Mains power
closed
closed
open
closed
open
applied
applied
NORMAL
Mains power
Mains power
Mains power
closed
open
open
closed
closed
applied
applied*
applied
Overload
Mains power
Mains power
Mains power
closed
open
open
closed
closed
applied
applied*
applied
Failure; TURBOVAC rotates
open
open
open
open
open
closed
open
open
* if selected
Table 3