Troubleshooting
37
GA 12.137/2.02 - 05/2002
Malfunction
12. One of the following messa-
ges is displayed:
RAM ERROR 1
RAM ERROR 2
ROM ERROR
EEPROM ERROR
13. Beginning with software Ver-
sion 3.03: The compressor unit
stops with error message
Restart active! and then restarts
automatically
14. Beginning with software Ver-
sion 3.03: The compressor unit
does not run; error message:
Restart fail!!!
15. Beginning with software Ver-
sion 3.03: The compressor unit
does not run; error message:
Brown outs!!!!
In addition to all displayed errors
SYSTEM ERROR is displayed.
Possible cause
—
The line voltage has failed either
completely or intermittently in one or
more phases. The compressor auto-
matically restarts after the malfunction
disappears.
Line voltage fails in one or more pha-
ses for longer than 5 minutes.
The line voltage has failed in one or
more phases at least 5 times within
10 minutes.
—
Recommended corrective action
Notify Leybold Service Department.
No action required unless
• the disruption lasts longer than 5 minutes
(
⇒
Restart fail!!! error message) or
• the disruption recurs 5 times in 10 minutes
(
⇒
Brown outs!!! error message)
Eliminate the cause of the disruption and then
restart the compressor unit. Use an uninterruptable
power supply if necessary.
Eliminate the cause of the disruption and then
restart the compressor unit. Use an uninterruptable
power supply if necessary.
—
Repair