The «DO 3 Deviation» display allows for defining the
«Valve in Position» signal. Press
2x
3x
to get to the
«Digital Outputs 1 to 4» display. »
to make the «Signal ON» setting.
to make the «Signal OFF» setting.
to adjust the «ON-delay».
to return to the
«Inputs/Outputs» display.
The Edit symbol is displayed in the «Signal ON»,
«Signal OFF» or «ON-delay» line. Press
to adjust a value.
to get to the
«Digital Inputs 1 to 4» display.
to save the new setting and return to the
«Configuration» display.
5.2.12
Analog Inputs/Outputs
The CMOVE 1250 has two analog inputs and four analog outputs. This menu informs on
the assignment of the analog inputs and outputs but it does not allow to make any settings
(Operation via inputs and outputs see chapter «5.4 Operation Via Inputs and Outputs»).
The «Configuration» display shows the current
settings of the operating mode, valve type, pressure
sensor, and nominal value
(setpoint) with source (I = internal, E = ex-ternal).
Press.
to get to the «Inputs/Outputs» display.
DO1-4
DO1-4
Signal ON : 10.0 %FS
Signal OFF : 10.0 %FS
ON-delay : 1 s
DO 3 Deviation
DO1-4
DO1-4
Signal ON : 10.0 %FS
Signal OFF : 10.0 %FS
ON-delay : 1 s
DO 3 Deviation
I/O
VALVE SENSOR I/O GEN.
Mode
:
Pressure
Valve
:
MOVE1250STD
Sensor : CTR1000T
Nom. I : 1.33E+01 mbar
Configuration