4511-xxx
2-88
Service Manual
Fuser power cable
LVPS/HVPS
Fuser
(continued)
Step 2: No continuity
Check the lamp cable for continuity.
• If correct, replace the fuser.
• If incorrect, replace the lamp cable.
Fuser
Disconnect the thermistor cable from J16 on the
controller card.
Measure the resistance across the ends of the
thermistor cable.
Replace the fuser assembly if the resistance is
lower than 1K ohm or shorted.
Note: Resistance measures approximately
240K ohms when cool and 1K ohms hot.
Fuser service check
FRU
Action
Содержание E238
Страница 14: ...4511 xxx xiii Service Manual Japanese Laser Notice Chinese Laser Notice ...
Страница 15: ...4511 xxx Laser notices xiv Korean Laser Notice ...
Страница 16: ...4511 xxx xv Service Manual ...
Страница 21: ...Safety information xx 4511 xxx ...
Страница 32: ...1 10 Service Manual 4511 xxx ...
Страница 144: ...4511 xxx 2 112 Service Manual ...
Страница 147: ...4511 xxx Diagnostic aids E238 E240 and E240n 3 3 Configuration Menu printout sample ...
Страница 148: ...4511 xxx 3 4 Service Manual Diagnostics mode printout sample ...
Страница 178: ...4511 xxx 3 34 Service Manual ...
Страница 203: ...4511 xxx Repair information 4 25 11 Loosen the screw E that secures the bracket to remove the cable E ...
Страница 230: ...4511 xxx 4 52 Service Manual ...
Страница 232: ...4511 xxx 5 2 Service Manual Rear view 3RZHU EXWWRQ 5HDU GRRU RXWSXW WUD 3DUDOOHO SRUW 86 SRUW WKHUQHW SRUW LI SUHVHQW ...
Страница 238: ...4511 xxx 6 2 Service Manual ...
Страница 240: ...7 2 Service Manual 4511 xxx Assembly 1 Covers ...
Страница 242: ...7 4 Service Manual 4511 xxx Assembly 2 Electronics ...
Страница 244: ...7 6 Service Manual 4511 xxx Assembly 3 Frame ...
Страница 248: ...7 10 Service Manual 4511 xxx ...
Страница 258: ...4511 xxx I 10 Service Manual ...