background image

                                                       

  

 

 

 

GENERAL INSTRUCTION GUIDE

 

EUROTHERM 2204 FM APPROVED LIMIT CONTROLLERS 

                                                                                                                                                                       

 

 

INDUSTRIAL OVENS 

 

This guide is provided by LEWCO, Inc. to assist its customers in becoming familiar with how LEWCO, Inc. sets 
up and uses the Eurotherm Controllers to test equipment prior to shipping.  This document does not replace 
respective Eurotherm user’s manuals and anyone using any of the Eurotherm products mentioned here is 
responsible for obtaining and understanding the user’s manual before using any of these controllers.  The user 
is responsible for setting up and configuring these devices to meet their own application requirements, not 
limited to, but including adjusting set points and setting up alarms.  

If you do not have a manual for your controller or wish to view an online version of it, please use the following 
link: 

http://www.eurothermonline.com/search?searchwords=manuals&searchsmall_4920=

 

2204FM: 

 

The 2204FM is a 1/4-DIN FM approved alarm indicator with two FM Approved form C relay outputs. Terminals 

AA, AB, and AC are dedicated to Alarm 1. Terminals 3A, 3B, and 3C are dedicated to Alarm 2. 

 

BUTTON LEGEND: 

 

 

OPERATION: 

 

If an alarm set point is exceeded or a sensor failure occurs, the alarm relays will change state. Once 

the sensor fault and PV return to a safe state and have been acknowledged the relays will return to 

their original state. 

 

 

 

 

 

 

Содержание EUROTHERM 2204FM

Страница 1: ...se devices to meet their own application requirements not limited to but including adjusting set points and setting up alarms If you do not have a manual for your controller or wish to view an online version of it please use the following link http www eurothermonline com search searchwords manuals searchsmall_4920 2204FM The 2204FM is a 1 4 DIN FM approved alarm indicator with two FM Approved for...

Страница 2: ...y reset The alarm can be acknowledged by pressing the PAGE button TO CHANGE ALARM SET POINTS NOTE If set point is shown in the lower display just press the UP and DOWN arrows If it is not shown follow the instructions below Press the PAGE button 1st on the left twice The display will show AL LIST To display the type of alarm that the instrument is set for press the SCROLL button and the alarm type...

Страница 3: ...the SCROLL button once and AL 1 will appear in the upper display and FSH will appear in the lower display use the UP arrow to change this to the desired alarm type FSH FSL or OFF For alarm 2 press the SCROLL button again and the upper display will read AL 2 and use the UP arrow to change this to the desired alarm type Press the PAGE button until upper display says EXIT and lower display says NO Ch...

Страница 4: ...pper display and OPER in the lower display Change OPER to CONF by pressing the UP arrow button Press the SCROLL button and the display will now show CONF in the upper display and 0 in the lower Change the 0 to a 2 using the UP arrow Press the PAGE button until you see INST in the upper display and CONF in the lower display Press the SCROLL button and you will see UNITS in the upper display and F o...

Страница 5: ...ss the SCROLL button until INPT appears in the upper display and the thermocouple type LEWCO Inc typically uses J J TC shows in the lower display Press UP or DOWN arrow until desired thermocouple type is shown Press SCROLL button again the upper display will read RNG L for range low The present value will be shown in the lower display This value can be changed by pressing the UP arrow the maximum ...

Страница 6: ...in the upper display and OPER in the lower display Change OPER to CONF by pressing the UP arrow Press the SCROLL button and the display will now show CONF in the upper display and 0 in the lower Change the 0 to a 2 using the UP arrow Press the PAGE button until you see IP in the upper display and CONF in the lower display Press the SCROLL button until you see rnG H appear in the uppder display and...

Отзывы: