background image

7

To create a unique name or modify text,

 under 

ABC

 (or 

Abc, abc

123

) use the up and down arrow 

buttons           to change each letter or numeral and 

side arrow buttons           to navigate. The       and       

buttons can be used to insert and delete characters.
Once your template or created 

name is displayed, press the 

center button       .Your device 

has now been included in 

the network with your chosen 

name. The RZCPG will confirm 

inclusion with the name displayed 

and prompt you to continue to 

INCLUDE DIM/SwCH

 by pressing the center button        

or to continue to the 

NEXT STEP

 by pressing the 

right soft key      .

Include Controller

NOTE:

 The 

INSTALL 

CHECKLIST

 screen will appear 

with the selection box around 

STEP 2 -

 

Include Controller

 

when 

NEXT STEP

 is chosen from 

STEP 1

.

Press the center button       on 

the RZCPG to bring up the 

INCLUDE CNTRLLER

 screen, 

where you will be prompted to 

place the controller in program 

mode.

NOTE: 

Leviton Controllers 

require an inclusion process 

that differs from Dimmers, Switches and Plug-In 

Modules. Controllers must be placed into program 

mode before they can be included into the network 

(refer to individual device instruction sheet).

Once your controller has been placed in program 

mode, press the center button       on the RZCPG. 

The RZCPG will go through the communication 

process and assign the node information for that 

device. 

The TEXT EDITOR

 will display where you 

can name your device 

(refer to TEXT EDITOR  

pg. 6)

.

x1

Back

Next Step

    Node included!
Node ID# 2:
Bedroom

More? Press

INCLUDE DIM/SWCH

STEP 2

x1

Return

INCLUDE CNTRLLER

Place controller
in program mode
See Instruction sheet

Begin? Press

x1

Back

INSTALL CHECKLIST

1. Include Dim/Swch
2. Include Controller
3. Update Controller
4. Create Areas
5. Set Associations

Next Step

 

ON 

 

ON 

 

ON 

 

ON 

OFF 

OFF 

OFF 

OFF 

x1 

12:00 PM 

M

o

n

 0

5

.0

1

.2

0

0

 6 

Default Pr

 ofil 

Stand By

M

en

u

 

ON 

 

ON 

 

ON 

 

ON 

OFF 

OFF 

OFF 

OFF 

x1 

12:00 PM 

M

o

n

 0

5

.0

1

.2

0

0

 6 

Default Pr

 ofil 

Stand By

M

en

u

1  

ON 

2  

ON 

3  

ON 

4  

ON 

OFF 

OFF 

OFF 

OFF 

x1 

12:00 PM 

Mon 05.01.200 6 

Default Pr ofil e 

Stand By

Menu

1  

ON 

2  

ON 

3  

ON 

4  

ON 

OFF 

OFF 

OFF 

OFF 

x1 

12:00 PM 

Mon 05.01.200 6 

Default Pr ofil e 

Stand By

Menu

1  

ON 

2  

ON 

3  

ON 

4  

ON 

OFF 

OFF 

OFF 

OFF 

x1 

12:00 PM 

Mon 05.01.200 6 

Default Pr ofil e 

Stand By

Menu

1  

ON 

2  

ON 

3  

ON 

4  

ON 

OFF 

OFF 

OFF 

OFF 

x1 

12:00 PM 

Mon 05.01.200 6 

Default Pr ofil e 

Stand By

Menu

Содержание Vizia RF RZCPG

Страница 1: ...Programmer Remote Cat RZCPG USER GUIDE Compatible with enabled products TM 1 ON 2 ON 3 ON 4 ON OFF OFF OFF OFF...

Страница 2: ...eas 9 10 Set Associations 10 11 Security 11 Install Complete 12 MAIN Menu screen 13 device list 13 who is 13 area 14 profile 14 15 events 15 16 settings 16 DATE TIME 16 CONTRAST 17 BUZZER 17 LOCATION...

Страница 3: ...ent has been tested and found to comply with the limits for a Class B Digital Device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful int...

Страница 4: ...RZCPG unless prompted otherwise MENU NAVIGATION and ICONS Navigating screens and menus on your RZCPG is accomplished using the following buttons x1 Back MAIN MENU 1 Device List 2 Who Is 3 Area 4 Profi...

Страница 5: ...ht side arrow buttons to toggle between choices x1 Cancel Save All Devices 1 All Devices 2 ON 3 Default Fade x1 Cancel Save All Devices 1 All Devices 2 ON 3 Default Fade 1 ON 2 ON 3 ON OFF OFF OFF x1...

Страница 6: ...ll Events are Disabled Buzzer OFF indication Buzzer OFF Buzzer ON Error Indication Event Recurrence One Time Event Date Time of Day or Dawn Dusk Offset Filter data on screen is filtered Power Adapter...

Страница 7: ...ller 4 Create Areas 5 Set Associations Next Step x1 Back 3 Update Controller 4 Create Areas 5 Set Associations 6 Security 7 Install Complete Next Step INSTALL CHECKLIST 5 1 ON 2 ON 3 ON 4 ON OFF OFF O...

Страница 8: ...ur device NOTE The right soft key will toggle from Template to Abc to ABC to abc to 123 and back to Template again This feature allows you to access the template names or to select capital undercase l...

Страница 9: ...ust be placed into program mode before they can be included into the network refer to individual device instruction sheet Once your controller has been placed in program mode press the center button o...

Страница 10: ...ll prompt you to stand within 3 feet of that controller Press the right soft key YES to update your controller NOTE It is important that you remain within 3 ft of the controller you ve selected from t...

Страница 11: ...nter button to select Add Devices which will bring up a list of the dimmers and switches you included in Step 1 to add to your new area Scroll to each device check box and use the and buttons to eithe...

Страница 12: ...ER ASSOC screen will display with the selection box around 1 Button prompting you to select the button on your controller that you wish to associate an area to Use side arrow buttons to toggle if appl...

Страница 13: ...e between choices OPEN RZCPG Lock and System Lock Press right soft key Save to complete NOTE Selecting RZCPG Lock will lock the RZCPG When you return to the HOME screen you will not have access to the...