background image

L5-20
L5-20
L6-20
L6-20
L7-20
L7-20
L8-20
L9-20
L14-20
L14-20
L15-20
L15-20
L16-20
L16-20
L21-20
L21-20
L22-20
L22-20
L23-20
L23-20
L5-30
L5-30
L6-30
L6-30
L7-30
L7-30
L8-30
L9-30
L14-30
L14-30
L15-30
L15-30
L16-30
L16-30
L17-30
L17-30
L21-30
L21-30
L22-30
L22-30
L23-30
L23-30

Ratings

125
125
250
250
277
277
480
600
125/250
125/250
3Ø250
3Ø250
3Ø480
3Ø480
3Ø120/208
3Ø120/208
3Ø277/480
3Ø277/480
3Ø347/600
3Ø347/600
125
125
250
250
277
277
480
600
125/250
125/250
3Ø250
3Ø250
3Ø480
3Ø480
3Ø600
3Ø600
3Ø120/208
3Ø120/208
3Ø277/480
3Ø277/480
3Ø347/600
3Ø347/600

Voltage, AC

Amps  Wiring

  20      2P, 3W
  20      2P, 3W
  20      2P, 3W
  20      2P, 3W
  20      2P, 3W
  20      2P, 3W
  20      2P, 3W
  20      2P, 3W
  20      3P, 4W
  20      3P, 4W
  20      3P, 4W
  20      3P, 4W
  20      3P, 4W
  20      3P, 4W
  20      4P, 5W
  20      4P, 5W
  20      4P, 5W
  20      4P, 5W
  20      4P, 5W
  20      4P, 5W
  30      2P, 3W
  30      2P, 3W
  30      2P, 3W
  30      2P, 3W
  30      2P, 3W
  30      2P, 3W
  30      2P, 3W
  30      2P, 3W
  30      3P, 4W
  30      3P, 4W
  30      3P, 4W
  30      3P, 4W
  30      3P, 4W
  30      3P, 4W
  30      3P, 4W
  30      3P, 4W
  30      4P, 5W
  30      4P, 5W
  30      4P, 5W
  30      4P, 5W
  30      4P, 5W
  30      4P, 5W

NEMA

CONFIG

*
*

3
3

*
*

5

*
*
*

5
5

10
10

5
5

10
10
15
15

*
*

5
5

*
*

10

*
*
*

10
10
20
20
25
25
10
10
20
20
25
25

HP

Rating

        Receptacle
     Type**

V0 Max Std
V0 Max CR
V0 Max Std
V0 Max CR
V0 Max Std
V0 Max CR
V0 Max Std
V0 Max Std
V0 Max Std
V0 Max CR
V0 Max Std
V0 Max CR
V0 Max Std
V0 Max CR
V0 Max Std
V0 Max Std
V0 Max Std
V0 Max Std
V0 Max Std
V0 Max Std
V0 Max Std
V0 Max CR
V0 Max Std
V0 Max CR
V0 Max Std
V0 Max Std
V0 Max Std
V0 Max Std
V0 Max Std
V0 Max CR
V0 Max Std
V0 Max CR
V0 Max Std
V0 Max Std
V0 Max Std
V0 Max Std
V0 Max Std
V0 Max Std
V0 Max Std
V0 Max Std
V0 Max Std
V0 Max Std

Cat. No.

 2310
 23CM10
 2320
 23CM20
 2330
 23CM30
 2340
 2350
 2410
 24CM10
 2420
 24CM20
 2430
 24CM30
 2510
 2510
 2520
 2520
 2530
 2530
 2610
 26CM10
 2620
 26CM20
 2630
 2630
 2640
 2650
 2710
 27CM10
 2720
 27CM20
 2730
 2730
 2740
 2740
 2810
 2810
 2820
 2820
 2830
 2830

              Plug
     Type**

Cat. No.

Power Indicator
Wetguard
Power Indicator
Wetguard
Power Indicator
Wetguard
Black&White
Black&White
Black&White
Wetguard
Black&White
Wetguard
Black&White
Wetguard
Black&White
Wetguard
Black&White
Wetguard
Black&White
Wetguard
Power Indicator
Wetguard
Power Indicator
Wetguard
Power Indicator
Wetguard
Black&White
Black&White
Black&White
Wetguard
Black&White
Wetguard
Black&White
Wetguard
Black&White
Wetguard
Black&White
Wetguard
Black&White
Wetguard
Black&White
Wetguard

2311-PLC
26W47
2321-PLC
26W48
2331-PLC
26W49
2341
2351
2411
26W74
2421
26W75
2431
26W76
2511
26W81
2521
26W82
2531
26W83
2611-PLC
28W47
2621-PLC
28W48
2631-PLC
28W49
2641
C2651
2711
28W74
2721
28W75
2731
28W76
2741
28W77
2811
28W81
2821
28W82
2831
28W83

Wiring

Diagram

1
1
2
2
3
3
4
5
6
6
7
7
8
8
9
9

10
10
11
11
12
12
13
13
14
14
15
16
17
17
18
18
19
19
20
20
21
21
22
22
23
23

7

**   To maintain an environmental rating of IP54 and NEMA 3R, Leviton EDSR enclosures do not require 

proprietary plugs or receptacles. Any (non-shrouded) NEMA mating plug or receptacle can be used. For an 

environmental rating of IP66, UL Standard 50, and NEMA environmental ratings of 4X and 12K, a Leviton 

WETGUARD

TM  

mating locking plug must be used.

Содержание PowerSwitch EDSR

Страница 1: ...Enclosed Disconnect Switch with Receptacle EDSR Cat No EDSR Rated 30A 600VAC Max INSTALLATION INSTRUCTIONS DI 000 0EDSR 00A PowerSwitch ...

Страница 2: ...ollowing DIN Rail mounted hardware A Rotary Switch 30A 660V with Normally Open Auxiliary Contact B Terminal Blocks Color Coded Blue terminal block is Neutral Green Yellow terminal blocks are ground 2 Inside Enclosure Base A Grounding Bracket with Screw B Four 4 Enclosure Mounting Feet with Screws Note Wall Mounting Hardware not included 3 Six 6 12 10 AWG Leads 3 Black 2 Green 1 White for internal ...

Страница 3: ...cal codes and the installation instructions WARNING Risk of electrical shock Disconnect all power supplies to enclosure before exposing interior More than one supply disconnect may be required to de energize this equipment before servicing WARNING Receptacle MUST be installed BEFORE connection to a power supply 30A MAXIMUM receptacle rating refer to ratings tables and wiring diagrams WARNING Separ...

Страница 4: ... secure to the enclosure base with the provided mounting screws 10 32 x 1 1 4 Torque to 10 12 in lbs 1 2 N m Conduit Hub Mounting Conduit Hub not included 1 Route wires Install 3 4 or 1 hub not included to conduit and enclosure For 3 4 hub drill a 1 1 16 mounting hole For a 1 hub drill a 1 5 16 mounting hole Ensure that the O ring seats on the enclosure base outside wall Install grounding bracket ...

Страница 5: ... coded Ground Terminal refer to Figures 2 3 3 Strip Gages and Torques for LINE and LOAD terminals For Neutral and Ground terminals use 14 8 AWG conductors strip to 15 32 12 0 mm Torque 7 1 8 9 in lbs 0 8 1 N m For Rotary Switch terminals use 14 8 AWG conductors strip to 11 16 17 5 mm Torque 7 in lbs 0 8 N m For Auxiliary terminals use 18 14 AWG conductors strip to 5 16 8 0 mm Torque 7 1 8 9 in lbs...

Страница 6: ...th 30A Gasket For 20A applications use 20A Gasket and 20A Gasket Clamp NOTE DO NOT MIX ASSEMBLY CONFIGURATIONS To Install SEAL COMPONENTS FOR A 20A RECEPTACLE FOR SAFETY MAKE SURE SWITCH IS IN THE OFF POSITION 1 Lift Receptacle Cover Unscrew pre assembled Gasket Clamp assembly and remove from box Set mounting screws aside 2 20A Gasket and Gasket Clamp are indentified with a 20A visible mark 30A Ga...

Страница 7: ... chart page 7 for the list of mating configurations The EDSR will work with all 20A and 30A NEMA Configurations For an environmental rating of IP66 while in use a Leviton WetguardTM plug must be used Gasket Clamp 20A Rubber Gasket 20A Environmental Rating Label EDSR V Ribs Mounting Screws 4 Gasket Clamp Assembly 30A Rubber Gasket and Gasket Clamp are pre installed with EDSR ...

Страница 8: ...d V0 Max CR V0 Max Std V0 Max CR V0 Max Std V0 Max Std V0 Max Std V0 Max Std V0 Max Std V0 Max Std V0 Max Std V0 Max Std V0 Max Std V0 Max Std Cat No 2310 23CM10 2320 23CM20 2330 23CM30 2340 2350 2410 24CM10 2420 24CM20 2430 24CM30 2510 2510 2520 2520 2530 2530 2610 26CM10 2620 26CM20 2630 2630 2640 2650 2710 27CM10 2720 27CM20 2730 2730 2740 2740 2810 2810 2820 2820 2830 2830 Plug Type Cat No Pow...

Страница 9: ...5 NEMA L9 20 Wire Diagram 11 NEMA L23 20 Wire Diagram 10 NEMA L22 20 Wire Diagram 9 NEMA L21 20 G Y X G N L3 L2 L1 T3 T2 T1 G W G N L3 L2 L1 T3 T2 T1 G N X G Y L3 L2 L1 T3 T2 T1 G N L3 L2 L1 T3 T2 T1 W G G Z Y X G N L3 L2 L1 T3 T2 T1 G Z Y X G N L3 L2 L1 T3 T2 T1 G Y W X G N L3 L2 L1 T3 T2 T1 G Y X G N L3 L2 L1 T3 T2 T1 W G Z Y X G N L3 L2 L1 T3 T2 T1 W G Z Y X G N L3 L2 L1 T3 T2 T1 W G Z Y X G N ...

Страница 10: ...m 22 NEMA L22 30 Wire Diagram 23 NEMA L23 30 Wire Diagram 21 NEMA L21 30 Wire Diagram 16 NEMA L9 30 G Y X G N L3 L2 L1 T3 T2 T1 G N G Y Z X W L3 L2 L1 T3 T2 T1 G N G Y Z X W L3 L2 L1 T3 T2 T1 G W Y X G N L3 L2 L1 T3 T2 T1 G N G Y Z X W L3 L2 L1 T3 T2 T1 G N G Y Z X L3 L2 L1 T3 T2 T1 G N G Y Z X L3 L2 L1 T3 T2 T1 G Y Z X G N L3 L2 L1 T3 T2 T1 G W G N L3 L2 L1 T3 T2 T1 W G G N L3 L2 L1 T3 T2 T1 G Y ...

Страница 11: ...NOTES ...

Страница 12: ... is disclaimed liability for labor for removal of this product or reinstallation This warranty is void if this product is installed improperly or in an improper environment overloaded misused opened abused or altered in any manner or is not used under normal operating conditions or not in accordance with any labels or instructions There are no other or implied warranties of any kind including merc...

Страница 13: ...ATION LEVITON INSTRUCTION SHEET MANUAL SPECIFICATIONS H2D 3 12 08 Helvetica DI 000 0EDSR 00A Black N A Final fold size 50 Lb offset Overall size 5 5 X 8 5 Booklet Paper size Saddle Stitch OVERALL SIzE 11 0 2 3 8 5 5 5 Booklet 8 5 FINAL SIzE Cat No 1 PowerSwitch TM ...

Отзывы: