7.
CLEANING AND MAINTENANCE
Attention! Before working on the equipment to do any work, always remove the power plug from the
socket.
Cleaning
•
Keep the ventilation slots of the appliance
clean to prevent overheating of the engine.
•
Regularly clean the appliance
housing with a soft cloth, preferably after each use.
•
If the dirt does not come off use a soft cloth moistened with soapy water.
IMPORTANT:
Never use solvents such as petrol, alcohol, ammonia water, etc. These solvents may damage
the plastic parts.
IMPORTANT:
Do not dip the vacuum cleaner into water or other liquids during cleaning, do not let any
liquids get into the motor unit.
Cleaning the collector
•
Empty and clean the collector
(15) after each use.
•
Dry the collector
carefully after the appliance
has been used for vacuuming up liquids.
Cleaning the
dust
filter
(Fig. N, O, P, Q, R, S)
•
After each use clean the dust filter
or sponge filter
.
•
Release the
clamps (11) and remove the motor unit (13) from the collector (15).
•
R
emove the
sponge filter (21) or
dust filter (19) from the motor unit
-
release the filter´s lock by turning
it and pull out.
•
Remove the filter protective mesh (20) from the dust filter
–
it is connected with Velcro slips.
•
Clean the dust filter and
mesh form the dust
by gently tapping on hard surface
.
Alternatively, use a soft
brush.
•
If the
dust
filter
or mesh
showing signs of excessive pollution, it can be rinsed in clean water with soap.
Before further use, leave the filter and mesh perfectly dry.
•
Cover tightly enclose the perimeter of the filter and secure with Velcro
slips
.
•
Replace the dust filter on the motor unit and secure it by filter´s lock
.
•
Sponge filter can be rinsed in clean water and left to dry.
8
. TROUBLESHOOTING
Before applying any of the solutions described in the trouble shooting section, disconnect the appliance
from the mains and allow it to cool down completely.
PROBLEM
REASON
SOLUTION
Vacuum power too
low.
The suction power slide (2) is wide open.
Close the slide (2).
The floor nozzle
(5) is blocked
Clean the floor nozzle
(5) of any
blockage.
Dust/Water container (15) is full.
Empty dust/water container (15) (
Cleaning and care).
Dust filter is dirty.
Clean dust filter (
Cleaning and care).
Motor unit does
not operate.
The unit is not switch on or power cord is
unplugged.
Check unit is plugged in and switched
on.