6.1.  Technical Specifications 

General 

Standards 

IEEE 802.3 10BASE-T Ethernet 
IEEE 802.3u 100BASE-TX Fast Ethernet 
IEEE 802.3ab 1000BASE-T Gigabit Ethernet 
IEEE 802.3z 1000BASE-SX/LX Gigabit Ethernet 

Protocol CSMA/CD 

Data Transfer 
Rate 

Ethernet: 10Mbps (half-duplex), 20Mbps (full-duplex) 
Fast Ethernet: 100Mbps (half-duplex), 200Mbps (full-duplex) 
Gigabit Ethernet: 2000Mbps (full-duplex) 

Topology Star 

Network Cables 

10BASET: 2-pair UTP Cat. 3, 4, 5; up to 100m 
100BASE-TX: 2-pair UTP Cat. 5; up to 100m 
1000BASE-T: 4-pair UTP Cat. 5; up to 100m 
Fiber module: mini-GBIC Fiber module 

Ports 

48 x 10/100Mbps 100BASE-TX Auto-MDIX RJ-45 
4 x 10/100/1000Mbps 1000BASE-T Auto-MDIX RJ-45 
2 x Combo mini-GBIC SFP slots 

Physical and Environmental 

AC inputs 

100-240V AC, 50-60 Hz internal power supply 

Power 
Consumption 

25 Watts (Max) 

Temperature 

Operating: 0~ 40C 
Storage: -10 ~ 70C 

Humidity 

Operating: 10% ~ 90% 
Storage: 5% ~ 90% 

Dimensions 

440 x 310 x 44 mm (W x H x D) 

EMI 

FCC Class A, CE Mark Class A, VCCI Class A 

 

Performance 

Transmits 
Method: 

Store-and-forward 

RAM Buffer: 

128KBytes per device 

Filtering 
Address Table: 

8K entries per device 

MAC Address 
Learning: 

Automatic update 

Packet Filtering 
/ Forwarding 
Rate: 

10Mbps Ethernet: 14,880/pps 
100Mbps Fast Ethernet: 148,800/pps 
1000Mbps Gigabit Ethernet: 1,488,000/pps 

 

 

41

Содержание GSW-5270

Страница 1: ...LevelOne GSW 5270 48 Port TP Fast Ethernet and 4 Port TP Gigabit w 2 Port shared SFP Web Smart Switch User Manual...

Страница 2: ...ii...

Страница 3: ...uses and can radiate radio frequency energy and if not installed and used in accordance with this user s guide may cause harmful interference to radio communications Operation of this equipment in a r...

Страница 4: ...S 7 Power and System 7 100BASE TX Port 1 48 Status 7 mini GBIC Port 49 50 Status 8 1000BASE T Port 49 52 Status 8 2 3 REAR PANEL 9 AC Power Connector 9 3 INSTALLATION 11 3 1 RACK MOUNTING 12 3 2 CONNE...

Страница 5: ...tion 33 System Setting 34 Trap Setting 35 Password Setting 36 Statistic 37 Factory Reset 38 Backup Setting 38 Firmware Upload 39 System Reboot 39 Logout 39 6 APPENDIX 41 6 1 TECHNICAL SPECIFICATIONS 4...

Страница 6: ...equirement of heavy duty bandwidth consuming applications Each RJ 45 port supports Auto MDIX allowing unlinking to another switch directly without cable selection hassle The two SFP interfaces allow y...

Страница 7: ...ection speed 10Mbps and 100Mbps Full duplex transfer mode for connection speed of 10Mbps 100Mbps and 1000Mbps Store and Forward switching scheme capability to support rate adaptation and ensure data i...

Страница 8: ...ents The carton should contain the following items GSW 5270 Web Smart Switch Power Cord Rack mount Kit Rubber Feet CD Manual Utility GSW 5270 Power Cord Rack mount Kit Rubber Feet CD Manual Utility If...

Страница 9: ...4...

Страница 10: ...ni GBIC Ports Port 49 50 The Switch is equipped with two combo mini GBIC ports supported optional 1000BASE SX LX mini GBIC module The 1000BASE T port 49 and 50 are the same ports with the mini GBIC po...

Страница 11: ...setting back to the factory default Note Note 1 When the port was set to Forced Mode the Auto MDI MDIX will be disabled 2 Be sure that you recorded the setting of your device else all the setting will...

Страница 12: ...r the power cord has improper connection SYS Management Indicator Blinking When the CPU is working the System LED is blinking On Off The CPU is not working 100BASE TX Port 1 48 Status Link ACT Link Ac...

Страница 13: ...rnet network Off No link 1000BASE T Port 49 52 Status Link ACT Link Activity Green When the Link ACT LED lights green the respective port is successfully connected to a 1000Mbps Gigabit Ethernet netwo...

Страница 14: ...following shows the rear panel of the Switch AC Power Connector This is a three pronged connector that supports the power cord Plug in the female connector of the provided power cord into this connec...

Страница 15: ...10...

Страница 16: ...tromagnetic field generators such as motors vibration dust and direct exposure to sunlight Leave at least 10cm of space at the front and rear of the hub for ventilation Install the Switch on a sturdy...

Страница 17: ...inch rack which can be placed in a wiring closet with other equipment Attach the mounting brackets at the switch s front panel one on each side and secure them with the provided screws Then use screw...

Страница 18: ...f Category 5 Cable These RJ45 ports are Auto MDI type port The Switch can auto transform to MDI II or MDI X type so you can just make an easy connection that without worrying if you are using a standa...

Страница 19: ...14...

Страница 20: ...the Web Management utility 1 Insert the Utility CD in the CD Rom Drive 2 From the Start menu on the Windows desktop choose Run 3 In the Run dialog box type D Utility setup exe D depends where your CD...

Страница 21: ...System word definitions in the Discovery List MAC Address Shows the device MAC Address IP Address Shows the current IP address of the device Protocol version Shows the version of the Utility protocol...

Страница 22: ...Address Shows the current IP address of the device MAC Address Shows the device MAC Address Protocol version Shows the version of the Utility protocol Product Name Shows the device product name Syste...

Страница 23: ...s clicked a Trap Information window will pop out it will show the trap information including the Symbol Time Device IP and the Event occurred The symbol represents the trap signal arise this symbol wi...

Страница 24: ...on then the Configuration Setting window will pop out after filling up the data that you want to change you must fill up the password and press the Set to process the data changed immediately The defa...

Страница 25: ...his function to update Firmware Upgrade Access Web Double click the device in the Monitor List or select a device in the Monitor List and press this Web Access button to access the device in Web brows...

Страница 26: ...nd file path Monitor Load To manually load the setting file of the Monitor List Exit To exit the Web Management Utility In the View TAB there are view log and clear log function this function will hel...

Страница 27: ...Subnet Mask 255 255 255 0 Default password admin Login Before you configure this device note that when the Web Smart Switch is configured through an Ethernet connection make sure the manager PC must...

Страница 28: ...Monitor List of the Web Management Utility to settle the device on the Web Browser When the following dialog page appears remain enter the default password admin and press Login to enter the main conf...

Страница 29: ...24...

Страница 30: ...There are fifteen options Port Setting IEEE 802 1Q VLAN Settings Trunk Setting Mirror Setting IEEE 802 1p Default Priority Broadcast Strom Control Setting System Information System Setting Trap Settin...

Страница 31: ...ch port s status selected drop down menu to set each port s Speed and QoS priority then press Apply button to activate changes To refresh the information table to view the latest port setting and Link...

Страница 32: ...Forced Mode settings 1000M Full 100M Full 100M Half 10M Full 10M Half Auto or Disable The default setting for all ports are Auto The 49 50 mini GBIC Gigabit Fiber connections can operate in Forced Mod...

Страница 33: ...therefore help to simplify network management by allowing users to move devices to a new VLAN without having to change any physical connections The IEEE 802 1Q VLAN Configuration page provides powerf...

Страница 34: ...LAN setting press the VID to modify that IEEE 802 1Q VLAN setting Modify VID Modify VID Asymmetric VLAN If asymmetric is enabled and port 1 for example receives an untagged packet the switch will appl...

Страница 35: ...h Up to six Trunk groups may be created each supporting up to 8 ports Add a Trunking Name and select the ports to be trunked together and click Apply to activate the selected Trunking groups Trunk Con...

Страница 36: ...work performances Mirror Setting Selection of the Sniffer mode is as follow TX transmit mode this mode will duplicate the data transmit from the source port and forward to the Sniffer port RX receive...

Страница 37: ...epending on your configuration 4 3 IEEE 802 1p Default Priority Setting Broadcast Storm Control Setting The Broadcast Storm Control feature provides the ability to control the receive rate of broadcas...

Страница 38: ...g Firmware Upload and System Reboot in System menu System Information Press on the System Information to present the system information status on this screen it will show the Product Name Firmware Ver...

Страница 39: ...ith an IP address network mask and default gateway before using the default or previously entered settings By default the IP setting is static mode By entering a System Name and System Location the de...

Страница 40: ...ng System Events Monitoring the system s trap Device Bootup a trap when booting up the system Illegal Login a trap when there is using a wrong password login and it will record from where the IP to be...

Страница 41: ...ing the old password and the new password two times press Apply for the changes to take effect If you forget the password press the Reset button in the front panel of the Switch the current setting in...

Страница 42: ...l show the status of each port packet count Statistics Refresh To renew the details collected and displayed Clear Counter To reset the details displayed To view the statistics of individual ports clic...

Страница 43: ...tory Reset Backup Setting The backup setting help you to backup the current setting of the Switch Once you need to backup the setting press the Backup button to save the setting To restore a current s...

Страница 44: ...To restore or upgrade firmware to the Switch you must specify the firmware file and press Upload button to proceed the firmware upload Firmware Upload System Reboot Provides to a safe way to reboot t...

Страница 45: ...40...

Страница 46: ...er module mini GBIC Fiber module Ports 48 x 10 100Mbps 100BASE TX Auto MDIX RJ 45 4 x 10 100 1000Mbps 1000BASE T Auto MDIX RJ 45 2 x Combo mini GBIC SFP slots Physical and Environmental AC inputs 100...

Страница 47: ...nd servers to Gigabit Ethernet can greatly improve network response times as well as significantly speed up the traffic between your subnets Gigabit Ethernet enables fast optical fiber connections to...

Страница 48: ...on disruptive and smooth evolution nature and the dominating potential market base virtually guarantees cost effective and high performance Fast Ethernet solutions 100Mbps Fast Ethernet is a standard...

Страница 49: ...network transmission capacity The switch acts as a high speed selective bridge between the individual segments The switch without interfering with any other segments automatically forwards traffic th...

Страница 50: ...AN is to reduce latency and need for routers using faster switching instead Other VLAN utility includes Security Security is increased with the reduction of opportunity in eavesdropping on a broadcast...

Отзывы: