4.2. Configuring the Switch
The 48+4-Port 10/100/1000Mbps Gigabit Ethernet Web Smart
Switch has a Web GUI interface for smart switch configuration.
The Switch can be configured through the Web Browser. A
network administrator can manage, control and monitor the
switch from the local LAN. This section indicates how to
configure the Switch to enable its smart functions
Default Setting
Default IP Address:
192.168.0.1
Default Subnet Mask:
255.255.255.0
Default password:
admin
Login
Before you configure this device, note that when the Web
Smart Switch is configured through an Ethernet connection,
make sure the manager PC must be set on same the IP
network. For example, when the default network address of the
default IP address of the Web Smart Switch is 192.168.1.1,
then the manager PC should be set at 192.168.1.x (where x is
a number between 2 and 253), and the default subnet mask is
255.255.255.0.
Open Internet Explorer 5.0 or above Web browser.
Enter IP address
http://192.168.0.1
(the factory-default IP
address setting) to the address location.
22