
C
HAPTER
4
| Configuring the Switch
Configuring Security
– 102 –
P
ARAMETERS
These parameters are displayed:
◆
Port
- Port Identifier.
◆
Policy ID
- An ACL policy configured on the ACE Configuration page
(
page 106
). (Range: 1-8; Default: 1, which is undefined)
◆
Action
- Permits or denies a frame based on whether it matches a rule
defined in the assigned policy. (Default: Permit)
◆
Rate Limiter ID
- Specifies a rate limiter (
page 103
) to apply to the
port. (Range: 1-15; Default: Disabled)
◆
Port Redirect
- Defines a port to which matching frames are re-
directed. (Range: 1-28; Default: Disabled)
To use this function, Action must be set to Deny for the local port.
◆
Mirror
- Mirrors matching frames from this port. (Default: Disabled)
To use this function, the destination port to which traffic is mirrored
must be configured on the Mirror Configuration page (see
"Configuring
Local Port Mirroring" on page 213
).
ACL-based port mirroring set by this parameter and port mirroring set
on the general Mirror Configuration page are implemented
independently. To use ACL-based mirroring, enable the Mirror
parameter on the ACL Ports Configuration page. Then open the Mirror
Configuration page, set the “Port to mirror on” field to the required
destination port, and leave the “Mode” field Disabled.
◆
Logging
- Enables logging of matching frames to the system log.
(Default: Disabled)
Open the System Log Information menu (
page 227
) to view any entries
stored in the system log for this entry. Related entries will be displayed
under the “Info” or “All” logging levels.
◆
Shutdown
- Shuts down a port when a macthing frame is seen.
(Default: Disabled)
◆
State
- Specify the port state:
■
Enabled
- To reopen ports by changing the port configuration in the
ACL configuration pages. (This is the default.)
■
Disabled
- To close ports by changing the volatile port
configuration of the ACL user module.
◆
Counter
- The number of frames which have matched any of the rules
defined in the selected policy.
Содержание GEL-2670
Страница 1: ...GEL 2670 24 GE 2 GE SFP L2 Managed Switch User Manual Ver 1 0...
Страница 2: ......
Страница 4: ......
Страница 6: ...ABOUT THIS GUIDE 6...
Страница 18: ...FIGURES 18...
Страница 20: ...TABLES 20...
Страница 22: ...SECTION I Getting Started 22...
Страница 34: ...SECTION II Web Configuration 34...
Страница 46: ...CHAPTER 3 Using the Web Interface Navigating the Web Browser Interface 46...
Страница 224: ...CHAPTER 4 Configuring the Switch Configuring sFlow 224 Figure 95 sFlow Configuration...
Страница 293: ...CHAPTER 7 Performing System Maintenance Managing Configuration Files 293 Figure 156 Configuration Upload...
Страница 294: ...CHAPTER 7 Performing System Maintenance Managing Configuration Files 294...
Страница 296: ...SECTION III Appendices 296...
Страница 314: ...GLOSSARY 314...
Страница 319: ......
Страница 320: ...Level 1 GEL 2670 E012013 KS R01...