User Manual "Level GB 200" доступен для бесплатного скачивания на нашем сайте. Этот руководство поможет вам разобраться с устройством и использовать его на полную мощность. Просто зайдите на manualshive.com и загрузите свой экземпляр прямо сейчас.
Set GB 200 with Built-in GSM Module
Two-way Converter of Phone Line on GSM
USER GUIDE
LEVEL
GSM GATE PROFESSIONAL
Страница 1: ...Set GB 200 with Built in GSM Module Two way Converter of Phone Line on GSM USER GUIDE LEVEL GSM GATE PROFESSIONAL ...
Страница 2: ...nsion exchange input free position for direct line or phone device to phone line connector ATTENTION GB 200 171 is source of phone line therefore never connect either direct or extension phone lines to connector GSM Gate 200 271 is on the contrary end device of phone line and is intended for extension lines of phone exchanges GB 200 271 can be used only on extension exchanges where engaged or dial...
Страница 3: ...hen Line Is Silent 11 5 15 Time for Pre set 11 5 16 Transmission of SMS Messages into PC 11 5 17 Switch on of SIM Card 12 5 18 Set up of Base SIM Card 12 5 19 Blocking of SIM Card by PIN 12 5 20 Assignment of SIM Cards to Allowed Pre selections 12 5 21 Number for Information SMS Messages 13 5 22 Set up of Number for Monthly Upkeep Calling 13 5 23 ALARM Inputs and Set up of A numbers for SMS Despat...
Страница 4: ...ply Dimension for current 600mA maximum power take off during call securing safety fuse T 1A Device must be disconnected from all power sources before maintenance or exchange of parts or filled boards No fluids must enter the device Danger of fire or injury by electric current impend Do not place device into rooms with high temperatures strong vibrations or high humidity In case you moved device f...
Страница 5: ...e 3 3 Insertion of SIM Cards Each SIM card includes PIN set by producer It is four figure number which is required by SIM card at start up of communication with GSM module if blocking of SIM card by PIN is active SIM card shall be inserted under sliding lid on left down corner of GB 200 Gently press the lid inside and down at its upper end If call is just not carried out supply of contacts in SIM ...
Страница 6: ...n which gate is installed You will hear dialling tone of GSM gate 2 Dial pppp where pppp are four figures of PIN for SIM1 PIN 0000 is set from production for SIM1 After entering correct PIN you will hear tone programming 3 Enter particular setting parameters Dial 4 figures of instruction followed by value of parameter for particular instruction 4 End entering of instruction by dialling Time contro...
Страница 7: ...mber Deleting of numeral or text data is carried out by substitution of parameter value by point or quotes 5 Control Instructions All parameters of GB 200 can be set from PC through serial line by phone in programming regime or by texts of instructions in SMS messages which follow after XXpppp 5 1 PIN in GSM Gate GB 200 So as GSM Gate co operates with SIM cards it is necessary to ensure that PIN S...
Страница 8: ...tion allows reconstruction of originally dialled number by adding of removed pre selection Instruction by Phone SMS Instruction Pre set 0100n PDIR n Not activated in production Where n is 0 to 7 figures which shall be added Removal of values by phone is carried out by instruction 0100 or by SMS message PDIR point represents data or PDIR Example Exchange removes pre selection 0 from dialled number ...
Страница 9: ...ver to second SIM card according to dialled number parameter No 19 SIMDIR set numbers of pre selections from longest to shortest Priority of evaluation goes from above Example You want to disallow usage of gate for Paegas and fixed phone lines and allow usage of number with pre selection 072 instead Enter programming regime with pppp see paragraph 4 2 Dial 0203 0204 0212 02140724 and hang up or se...
Страница 10: ...er of extension to which incoming calls shall be connected if no pre set is received Removal of values is carried out by instruction 0400 or by SMS message IDIR point represents parameter or IDIR 5 6 Ringing after Connection Some exchanges require ringing after initial connection of line onto input transmitter This function allows setting of switch on of control ringing for required time Function ...
Страница 11: ...ers which always have maximum number of 10 figures it is sensible to set 10 as maximum number of figures After setting of 10th figure dialling of number starts immediately without necessity of waiting for control Instruction by Phone SMS Instruction Pre set 0900nn LDIAL nn 10 set from production Where nn is number in range from 03 to 24 and means maximum number of figures 5 11 Set up of Dial Tone ...
Страница 12: ...or Pre set During incoming call from GSM gate GB 200 271 picks up extension line and awaits pre set by frequency dialling from cell phone for set time If pre set is not carried out set number of extension is automatically dialled by pulse dial see chapter 5 4 Instruction by Phone SMS Instruction Pre set 1400ss WAIT ss 5 tm 5s set from production Where ss is 1 to 25 s Transit of frequency pre set f...
Страница 13: ...Phone SMS Instruction Pre set 1701z SIMPRIM1 z SIM1 1 set from production 1702z SIMPRIM2 z SIM2 0 set from production Where z is number 0 or 1 0 SIM is not base 1 SIM is base 5 19 Blocking of SIM Card by PIN If your SIM card is blocked by PIN for safety reasons it is necessary to ensure that this PIN is entered at each switch on of GSM module Activation of this function for SIM1 or SIM2 ensures au...
Страница 14: ... longest to shortest Priority of evaluation goes from above 5 21 Number for Information SMS Messages GB 200 allows automatic dispatch of information about changes in configuration operation time and about RESET Information is sent as SMS message to set cell phone number if this number is entered in following way Instruction by Phone SMS Instruction Pre set 2000n INFOSMS n Not activated in producti...
Страница 15: ...commended linkage of input example for input No 2 Connector CANNON15 Description of linkage of outlets 1 8 input output No 1 8 9 input INIT 10 14 GROUND 15 5V max 400mA Since output works at the same time also as input set up of logical level 0 on output avoids activation of dispatch of SMS message from particular input see chapter 5 26 function OUTv h Counterpart of connector CANNON15 including p...
Страница 16: ...entered as numeric values according to ASCII table through phone line in SMS message text is closed into quotes 5 27 Set up of Logical Level of Outputs Each input No 1 8 is also output at the same time Value of logical level of particular output can be changed in following way Instruction by Phone SMS Instruction Pre set 260vh OUTv h log 1 for all outputs set from production Where v is number of i...
Страница 17: ... 5 28 Instruction by Phone SMS Instruction Pre set INIT SMS message as well as all other SMS instructions requires entering of heading with actual PIN of SIM card XXpppp in front of instruction see chapter 4 2 If you do not know this PIN it is necessary to carry out configuration from PC or hardware initialisation in following way Interconnect PINs No 9 and 10 of connector CANNON15 and simultaneou...
Страница 18: ... ADIR16 n n 1 7 figures or n clears out parameter value 1 2 3 4 5 6 7 8 9 0 Code for disallowed directions 0300n CDIR n n or 1 7 figures Fixed pre set 2 0400n IDIR n n or 1 7 figures Ringing after switch on 1 0500xx IRING xx xx 00 20 s 10 8s 10 Delay before dial 1 0600xx DELAY xx xx 00 20 s 10 3s 10 Waiting for dial 0700ss TLINE ss ss 10 99 s 60s Time of number control 0800ss TDIAL ss ss 01 20 s 4...
Страница 19: ... m 1 SIM1 m 2 SIM2 all 0 Number for info SMS 2000n INFOSMS n n or 1 15 figures Number for monthly calling 2100n MCALL n n or 1 15 figures Number SMS ALARM A 220vn SMSNOAv n v input 1 8 n or 1 15 figures Number SMS ALARM B 230vn SMSNOBv n v input 1 8 n or 1 15 figures Numbers for ALARM calling 240vn ALARMCALLv n v input 1 8 n or 1 15 figures Set up of SMS message texts 250vtext SMSTXTv text v input...
Страница 20: ...level of GSM signal 8 3 GBserver Program for Distribution of SMS Messages between GB200 and Network Client Program running on PC to which GB 200 is connected allows distribution of incoming and outgoing SMS messages between GB 200 and clients of computer LAN net Basic functions of program are Set up of communication port or GB 200 Set up of port of TCP network protocol on LAN net Pre set communica...
Страница 21: ...ction 20 60 Hz Transmission of fixed pre set Dial pulse Line voltage 24 60 V Tones 425 Hz SMS inputs CANNON15 No 1 8 log 0 0 0 8 V log 1 3 8 12 V SMS outputs CANNON15 No 1 8 log 0 max 0 4 V max Iz 300mA log 1 3 5 5 V at Iz 0 3mA CANNON15 No 15 5V max load 200 mA GSM network GSM 900 MHz 1800 MHz SIM card Plug in Device Power supply voltage 10 5 16V ss network adapter12 V 500mA Power take off Max 6 ...
Страница 22: ...21 GUARANTEE CERTIFICATE Product name Type Production number Date of sale Signature Selling organisation Address phone No stamp Date of receipt Date of dispatch Description of defect ...
Страница 23: ...tee Certificate damage of product caused by natural disaster during transport by unsuitable positioning unsuitable handling operation of device in unsuitable conditions or in case of damage or removal of sealing labels Guarantee does not apply to expendable property dyeing ribbons floppy discs etc It does not apply to malfunction caused by installed software or interference too Company is not resp...
Страница 24: ...23 GB 200 003 C LEVEL 2002 LEVEL Ltd Plhovská 1997 Nachod 547 01 CZECH REPUBLIC www levelna cz ...