Figure 4.5: Managing parameter sets in the MA 30
The parameter sets are not erased by switching off the operating voltage.
The current parameter set is used on start-up. If this is invalid, the custom-
er-specific parameter set is loaded.
"parameter copy"
command
With the online command
p
arameter
c
opy
, abbreviated "
pc
", you can copy a
given parameter set as a backup, so to speak, into the customer-specific
parameter set and use a hardware RESET to return the read station to this
state at any time (see chapter 4.6.2).
PC
BCL
MA 30/31
"pc01"
Factory
parameter set
"2"
Structure of the parameter set
Customer-
specific
parameter set
"1"
Current
parameter set
"0"
"pc10" or cold start "custom-
er-specific parameter set"
"Parameterise"
online/off-line setup
or
PLC
BCL parameter
(MA 30 only)
MA 30/31
parameter
Cold start "factory
parameter set"
"pc20"
MA 30 only
Commands for handling the parameter sets via software:
pc01:
copies the current parameter set to the customer-specific parameter
set
pc10:
copies the customer-specific parameter set to the current parameter
set (corresponds to hardware RESET with customer-specific
parameters)
pc20:
copies the Leuze factory parameter set to the current parameter set