Connector Unit MA 30 / MA 31
Leuze electronic
Commissioning
Leuze
electronic
4.3
multiNet settings
Figure 4.3: multiNet menu default settings
This setting applies for the normal "multiNet" operating mode.
Under "Last slave address", you can set the number of connected slaves.
This is analysed only when the rotary switch is in position "0", i.e. the
last
slave address
is not set via hardware.
Figure 4.4: Setting the "multiScan" operating mode
The "multiScan" operating mode is required when multiple scanners are to
read the same bar code. From the outside, the scanner system appears as a
single unit, i.e. the MA 30 sends only one (the first found) read result to the
controller.
This application is designed for only
one
label per reading gate.
Triggering is performed either by online command "+" to the Master or by
hardware switching input, which can only be connected to the Master.
In the "multiScan" operating mode, the MA 30 functions by default without an
address on the host interface. Because of this, this operating mode is active
only when the service interface is
not
activated!
Under "Last slave address", you can set the number of connected slaves.
This is analysed only when the rotary switch is in position "0", i.e. the "last
slave address" is not set via hardware.