Mounting
Leuze electronic GmbH + Co. KG
MSI-TR1B / MSI-TR2B
16
S
[mm]
= Safety distance
t
a
[s]
= Response time of the protective device
t
i
[s]
= Response time of the safety relay
t
m
[s]
= Machine stopping time
t
t
[s]
= Test interval time of safety relay
Table 6.2:
Values for t
i max
6.1.2 Multi-axis arrangement
Figure 6.1: With multi-axis installation, the light beams must run parallel to the reference plane (e.g.
floor) and must be aligned mutually parallel.
The beam directions are to be set oppositely in each case (See Figure 6.2:). Otherwise, the light beams
could cause mutual interference and disturb reliable function.
a
Transmitter
b
Receiver
Figure 6.2: Multi-axis arrangement
6.1.3 Minimum distance to reflective surfaces
Device
t
i max
[ms]
MSI-TR1B
80
MSI-TR2B
150
NOTE
If longer stopping times are determined during regular inspections, an appropriate additional
time must be added to t
m
.
S
1600 mm t
a
t
i
t
m
t
+
+
t
+
850 mm
+
=
a
a
a
b
b
b
WARNING
Failure to maintain minimum distances to reflective surfaces may result in serious injury!
Reflective surfaces can indirectly deflect the transmitter beams to the receiver. In this case, inter
-
ruption of the protective field is not detected.
Make certain that all reflective surfaces are the necessary minimum distance away from the
protective field.