Configuration control
Leuze electronic
DCR 50
54
Code Description
Command Format Op-
tions
Default Notes/Examples
Set Imager Exposure
SC
SP
S/P/R/
G
EX
This defines the imager exposure in
Bypass AGC Mode.
Example
: SCSPSEX50
Set Imager Gain
SC
SP
S/P/R/
G
GN
This defines the imager gain in Bypass
AGC Mode.
Example
: SCSPSGN50
Set Imager Illumination
SC
SP
S/P/R/
G
IL
This defines the Imager Illumination in
Bypass AGC Mode.
Example
: SCSPSIL50
Set Fixed percent (percent)
SC
SP
S/P/R/
G
FP
Set Fixed percent
Valid Range: 0 to 100
Example:
8.2.12 Setup AGC parameters
Code Description
Command Format Op-
tions
De-
fault
Notes/Examples
Get All AGC Parameters
AG
AG
G
Returns all AGC parameters values in
an XML element.
Example
: AGAGG
Max AGC Brightness in Mo-
tion Detect (percent)
AG
CR
S/P/R/
G
MB 100
Sets the maximum brightness used wile
in Motion Detect mode.
An integer from 0 to 100 representing a
percentage of overall maximum bright-
ness.
Valid Range: 0 to 100
Example
: AGCRPMB50
AGC Timing
AG
TM
S/P/R/
G
HQ 360
AGC High Quality time limit
Valid Range:
Example
: AGTMSHQ360
AGC Medium Quality time
limit
AG
TM
S/P/R/
G
MQ 320
AGC Medium Quality time limit
Valid Range:
Example
: AGTMSMQ320
AGC Low Quality time limit
AG
TM
S/P/R/
G
LQ
120
AGC Low Quality time limit
Valid Range:
Example
: AGTMSLQ120
Timeout multiplier (FP24_8)
AG
TM
S/P/R/
G
MT
0x100
Timeout multiplier (FP24_8)
Valid Range:
Example
: AGTMS