Configuration control
Leuze electronic
DCR 50
49
Code Description
Command Format Op-
tions
De-
fault
Notes/Examples
Public sector & validation
configuration string
CD OP
S/P/R/
G
FP
Validation & public sector configuration
string
Example
: CDOPSFP
Stand Detection
CD ST
S/P/R/
G
SE
1
0
Disable
Example
: CDSTSSE0
1
Enable
Example
: CDSTSSE1
Detects when the reader has been
placed in a stand that contains a trigger
magnet and change to Motion Detection
mode.
CD ST
S/P/R/
G
SD
CDSTSSD100
Stand detect duplicate barcode block
delay in ms
8.2.6
Power mode parameters
Code Description
Command Format Op-
tions
De-
fault
Notes/Examples
Get All Power Management
Parameters
PM PM
G
Returns all power management parame-
ter values in an XML element.
Example
: PMPMG
Standby Mode Timer
PM SB
S/P/R/
G
EN
0
0
Disable Standby Mode Timer
Example
: PMSBSEN0
1
Enable Standby Mode Timer
Example
: PMSBSEN1
Standby Mode Timer Delay
(ms)
PM SB
S/P/R/
G
VA
5000
If Standby Mode Timer is enabled, the
device will go into Standby Mode after
this timer has expired.
Valid Range:
Example
: PMSBSVA2000
Sleep Mode Timer
PM SM
S/P/R/
G
EN
0
0
Disable Sleep Mode Timer
Example
: PMSMSEN0
1
Enable Sleep Mode Timer
Example
: PMSMSEN1
The Standby Mode Timer must be en-
abled for the device to go into Sleep
Mode.
Sleep Mode Timer Delay
(ms)
PM SM
S/P/R/
G
VA
3600
If both Standby Mode Timer and Sleep
Mode Timer are enabled, the device will
go into Sleep Mode after this timer has
expired.
Valid Range:
Example
: PMSMSVA3600