Configuration control
Leuze electronic
DCR 50
31
Code Description
Command Format Op-
tions
De-
fault
Notes/Examples
GS1 DataBar
SY
GS1
D
S/P/R/
G
EN
1
0
Disable
Example:
SYGS1DSEN0
1
Enable
Example:
SYGS1DSEN1
GS1 DataBar Omnidi-
rectional & truncated
SY
GS1
D
S/P/R/
G
OT
0
0
Disable
Example:
SYGS1DSOT0
1
Enable
Example:
SYGS1DSOT1
GS1 DataBar Stacked
SY
GS1
D
S/P/R/
G
ST
1
0
Disable
Example:
SYGS1DSST0
1
Enable
Example:
SYGS1DSST1
GS1 DataBar Expanded SY
GS1
D
S/P/R/
G
EX
1
0
Disable
Example:
SYGS1DSEX0
1
Enable
Example:
SYGS1DSEX1
GS1 DataBar Expanded
Stacked
SY
GS1
D
S/P/R/
G
ES
1
0
Disable
Example:
SYGS1DSES0
1
Enable
Example:
SYGS1DSES1
GS1 DataBar Limited
SY
GS1
D
S/P/R/
G
LI
1
0
Disable
Example:
SYGS1DSLI0
1
Enable
Example:
SYGS1DSLI1
Han Xin – Get All Pa-
rameter
SY
HAX
N
G
Returns all Han Xin parameter values in
an XML element.
Example
: SYHAXNG
Han Xin
SY
HAX
N
S/P/R/
G
EN
0
0
Disable
Example:
SYHAXNSEN0
1
Enable
Example:
SYHAXNSEN1
Han Xin – Polarity
SY
HAX
N
S/P/R/
G
PO
0
0
Normal mode enabled - Black on
white background
Example:
SYHAXNSPO0
1
Inverse mode enabled - White on
black background
Example:
SYHAXNSPO1
2
Both normal and inverse modes
enabled
Example:
SYHAXNSPO2
Note:
This setting value is ignored if
Han Xin decoding is disabled