![Leuze DCR 258i Скачать руководство пользователя страница 92](http://html1.mh-extra.com/html/leuze/dcr-258i/dcr-258i_original-operating-instructions_1883777092.webp)
EtherNet/IP
Leuze electronic GmbH + Co. KG
DCR 258i
92
Services:
• Get Attribute Single 0x0E
• Set Attribute Single 0x10
Tab. 10.2:
Structure of the class "Device application status and control 110 / 0x6E"
Path
Designation
Size in
bit
Data
type
Default
(dec)
Min
(dec)
Max
(dec)
Access
Cl.
Inst.
Attr.
110
1
1
Device application
status
16
U16
0
0
65535
Get
2
Device application
control
16
U16
0
0
65535
Set
This section describes the specific bits in attributes 1 and 2 of class 110 Device application status and con-
trol.
Tab. 10.3:
DCR 258i input data structure – Device application status
Byte
Bit 7 Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Reserved
Neg. ref. com-
parison
Pos. ref. com-
parison
Negative de-
coding
Positive decod-
ing
1
Reserved
Tab. 10.4:
DCR 258i output data structure – Device application control
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Reserved
Reference
code teach
Auto Setup
1
Reserved
Positive decoding
0: No decoding
1: Decoding order successfully completed
Negative decoding
0: No decoding
1: Decoding order NOT successfully completed
Positive reference code comparison
0: No comparison
1: Positive reference code comparison
Negative reference code comparison
0: No comparison
1: Negative reference code comparison
Reference code teach
0 > 1: Starts with teach-in of the reference code
Auto Setup
Starts and stops the auto setup function.
0 > 1: Start auto setup
1 > 0: Stop auto setup