EtherNet/IP
Leuze electronic GmbH + Co. KG
DCR 258i
88
Buffer overflow
This signal indicates that all result buffers are occupied and that the sensor rejects data:
0: No
1: Yes
New result (toggle bit)
The toggle bit indicates whether a new result is present:
0 > 1: New result
1 > 0: New result
Waiting for acknowledgment
This signal represents the internal state of the control:
0: Base state
1: Control waiting for acknowledgment from the master
Result data length
Data length of the actual result information. If the result information fits in the selected assembly length, this
value reflects the length of the transmitted data. A value larger than the assembly length indicates a loss of
information caused by an assembly length which has been selected too small.
Data
Result information with a length of max. 255 bytes.
Activate result fragmentation
This attribute specifies whether the messages from the sensor to the control should be transferred in frag-
ments:
0: Fragmentation inactive
1: Fragmentation active
Fragment number
Current fragment number
Remaining fragments
Number of fragments which still have to be read for a complete result.
Fragment size
The fragment size corresponds to the projected fragment length, except for the last fragment.
10.6.6 Class 108 – Entry data
NOTICE
The entry data are the data from the control to the sensor.
This class defines the transfer of entry data to a command interpreter in the sensor. This class also defines
the transfer of fragmented entry data. To occupy few I/O data, the entry data may be split into several frag-
ments with this class. The fragments can then be transmitted one after another with a handshake.
Object class 108 = 0x6C
Services:
• Get Attribute Single 0x0E
• Set Attribute Single 0x10