Configuration / device parameters
Leuze electronic GmbH + Co. KG
BPS 8
48
Copying and pasting devices
It is possible to copy and paste individual devices. To do this, the device to be copied must be selected.
By clicking on the right mouse button, the Copy and Paste functions become available. Only the device
settings are copied, not the deposited interface data of the PC.
Renaming devices
It is possible to rename individual devices. This requires the respective device to be selected. Right click
on the mouse button, select Device properties… and enter the desired description under Name.
Graphical configuration
If a device is selected via the left mouse button, the window of the graphical configuration opens automat
-
ically. The graphical interface visualizes the device settings and these can be loaded or transferred using
the symbols and
.
For further help on device-specific parameters, the technical description for the selected device may be
opened. To view the technical description of the device, click on the
symbol.
All parameters that were changed, i.e. that deviate from the Leuze factory settings, have a yellow back
-
ground or frame color or are marked with the
symbol for better orientation.
To reset all parameters of the selected device back to the Leuze factory settings, click on the
symbol.
This only resets the values in the PC and not the settings in the BPS.
Tree structure configuration
The second option for working off-line is the tree structure. The tree structure contains all settings of the
graphical structure plus additional parameters.
Terminal
The third option of communicating with the device is the terminal. This is only possible online.
If no device is selected, only the terminal is available. Its interface settings are available under Options ->
Communication…. They can also be selected by clicking on the communication parameters displayed in
the lower status bar.
NOTE
When creating an individual device, the Leuze standard parameter set is always created
together with the selected device according to the software version selected. The interface data
from the PC to the device are also created together with the Leuze standard settings.
These are:
• Data format:
9600 / 8 / 1 / None
• Framing protocol: <STX><data><CR><LF>
• Address:
none
Display erroneous parameters
Display changed parameters
Display all parameters
Close all parameters