Address setting
In the modular hoods with integrated connectors MS 34 103 and MS 34 105, the
PROFIBUS address can be set via two rotary switches and one slide switch.
The address switches are positioned as follows.
Figure 7.5:
View of the inside of the MS 34
7.4
Connection
Attention!
Do not open the device yourself under any circumstances! There is otherwise a risk of un-
controlled emission of laser radiation from the device. The housing of the BCL 34 contains
no parts that need to be adjusted or maintained by the user.
Before connecting the device, be sure that the supply voltage agrees with the value printed
on the nameplate.
Connection of the device and maintenance work while under voltage must only be carried
out by a qualified electrician.
The power supply unit for the generation of the supply voltage for the BCL 34 and the re-
spective connector units must have a secure electrical insulation through double insulation
and safety transformers according to DIN VDE 0551 (IEC 742).
Be sure that the functional earth is connected correctly. Unimpaired operation is only guar-
anteed when the functional earth is connected properly.
If faults cannot be corrected, the device should be removed from operation and protected
against possible use.
Slide switch for the hundreds is marked with 10
2
*
Rotary switch for the tens is marked with 10
1
Rotary switch for the single digits is marked with 10
0
Connector to the BCL 34
*Switch position
Top
address
100 - 126
Bottom address
1 - 99