Specifications
18
BCL 34
Leuze electronic
Table 5.1:
General Specifications
Notice!
The warm-up time before devices with integrated heating are ready for operation is
approx. 30min. (depending on the environmental conditions).
5.2
LED indicators
MS 34 103 / MS 34 105
On top of the modular hood with integrated connectors a red/green status LED is located
between the M12 connectors HOST/BUS IN and BUS Out. It indicates the state of the
PROFIBUS connection.
Environmental data
Ambient temp. (operation/
storage)
without heating: 0°C … +40°C/-20°C … +60°C
with heating:
-35°C … +30°C/-20°C … +60°C
Air humidity
max. 90% rel. humidity, non-condensing
Vibration
IEC 60068-2-6, test FC
Shock
IEC 60068-2-27, test Ea
Electromagnetic
compatibility
EN 61326-1,
IEC 61000-4-2, -3, -4 and -6,
Additional Functions
autoReflAct
automatic reading activation via reflector
State
Meaning
off
voltage off or device not yet recognised
1)
by the PROFIBUS
1)
Note: The LED remains off until the BCL 34 is recognised by the PROFIBUS. Only after
the PROFIBUS has addressed the BCL 34 for the first time do the following status
descriptions apply.
green flashing
initialisation of the device, establishment of the PROFIBUS communication
green, continuous
light
data operation
red, flashing
error on the PROFIBUS, error can be resolved by a reset
red, continuous light error on the PROFIBUS, error cannot be resolved by a reset
orange, continuous
light
SERVICE operation active
Table 5.2:
LED states MS 34 103 / MS 34 105