PROFIBUS
Leuze electronic
BCL 34
81
TNT
35/7-2
4
V
8.3.31
Code type
Module 45
The module defines the input data for the communication of the code type of the currently
transmitted barcode.
Parameters
none
Input Data
Output Data
none
Input Data
Description
Rel.
addr.
Data
type
Value Range
Default
Unit
CR to
module
Code type
Code type of the transmitted bar-
code
0
unsign8
0:
No code
1: 2/5
Interleaved
2:
Code39
6: UPCA,
UPCE
7:
EAN8, EAN13
8: Code128,
EAN128
9: Pharmacode
10: EAN Addendum
11: Codabar
12: Code93
0
–
Input data length: 1 byte