Recommended settings
Observation
Measure
Action
After teaching, the yellow
LED and the switching
output flicker if the label is
moved through the sen-
sor:
The function reserve on
the label is too low.
Reduce sensitivity of the
sensor
(upward shift of the
switching threshold)
Repeatedly press the mi-
nus button (-) briefly until
the sensor detects the
moving label stably and
without interruption.
In rare cases, a highly in-
homogeneous carrier
tape can affect the func-
tional reliability. The yel-
low LED and the switch-
ing output flicker if the
blank carrier tape is
moved through the sensor
without labels:
The function reserve on
the carrier is too low.
Increase sensitivity of the
sensor
(downward shift of the
switching threshold)
Repeatedly press the
teach button (+) briefly
until the sensor detects
the moving carrier tape
without labels stably and
without flickering.
Manual locking/unlocking of the buttons on the device
To protect against erroneous operation, the locking of the buttons is intended to
prevent a button on the device from accidentally being pressed. Accidental button
actuation could unintentionally trigger the
easyTune function or the teaching of the
device.
7
Ä
Press the teach button (+) and the minus button (-) simultaneously until the
green ON LED flashes at approx. six times per second.
Ä
Release the teach button (+) and the minus button (-).
ð
The buttons are now locked and can no longer be operated.
ð
The buttons are unlocked using the same button combination.
NOTICE
Manual locking of the buttons on the device is stored in volatile mem-
ory.