background image

Recommended settings

Observation

Measure

Action

After teaching, the yellow
LED and the switching
output flicker if the label is
moved through the sen-
sor:
The function reserve on
the label is too low.

Reduce sensitivity of the
sensor
(upward shift of the
switching threshold)

Repeatedly press the mi-
nus button (-) briefly until
the sensor detects the
moving label stably and
without interruption.

In rare cases, a highly in-
homogeneous carrier
tape can affect the func-
tional reliability. The yel-
low LED and the switch-
ing output flicker if the
blank carrier tape is
moved through the sensor
without labels:
The function reserve on
the carrier is too low.

Increase sensitivity of the
sensor
(downward shift of the
switching threshold)

Repeatedly press the
teach button (+) briefly
until the sensor detects
the moving carrier tape
without labels stably and
without flickering.

Manual locking/unlocking of the buttons on the device

To protect against erroneous operation, the locking of the buttons is intended to
prevent a button on the device from accidentally being pressed. Accidental button
actuation could unintentionally trigger the 

easyTune function or the teaching of the

device.

7

Ä

Press the teach button (+) and the minus button (-) simultaneously until the
green ON LED flashes at approx. six times per second.

Ä

Release the teach button (+) and the minus button (-).

ð

The buttons are now locked and can no longer be operated.

ð

The buttons are unlocked using the same button combination.

NOTICE

Manual locking of the buttons on the device is stored in volatile mem-
ory.

9

EN

Содержание 50142875

Страница 1: ...GSU 14E Ultrasonic label fork Leuze electronic GmbH Co KG info leuze com In der Braike 1 73277 Owen Tel 49 7021 573 0 We reserve the right to make changes 2020 04 23 50143645 www leuze com...

Страница 2: ...1Bildteil 1 A B 2 12 s 2 7 s C B A D 7 s 2...

Страница 3: ...3 4 2 7 s 5 12 s 3...

Страница 4: ...6 2 s 2 s 7 7 s 8 A B C t HIGH LOW t 100 ms t 20 ms D E t 20 80 ms 20 ms 4...

Страница 5: ...9 A B T t HIGH LOW 20 ms 20 ms 10 5...

Страница 6: ...l material used determines the achievable precision and the reliability of gap detection between labels Light switching signal in the label gap Dark switching signal on the label 1 A Label center posi...

Страница 7: ...chronously Release the teach button Allow the label tape to advance through the sensor at a maximum speed of 50 m min The sensor indicates the belt transport by a more rapid synchro nous flashing of t...

Страница 8: ...signal on the label For the taught switching threshold there is a high function reserve in both the gap as well as on the label and the sensor functions reliably To achieve a better function reserve...

Страница 9: ...the sensor downward shift of the switching threshold Repeatedly press the teach button briefly until the sensor detects the moving carrier tape without labels stably and without flickering Manual lock...

Страница 10: ...ated C Teach is started D Teach duration Note During the teach duration the label tape must be transported through the sensor see chapter Manual teach while the label tape is passing through dynamic E...

Страница 11: ...s also possible to lock the buttons via the teach input pin 5 A static high signal 20 ms on the teach input locks the buttons on the de vice so that no manual operation is possible The buttons can the...

Отзывы: